Commissioning

BEFORE COMMISSIONING, ENSURE THAT THE POWER TO THE UNTI IS TURNED OFF AS THE PUMP MAY BE

SERIOUSLY DAMAGED IF RUN DRY.

Carefully attach the hose to the Aquastream Thermo outlet. Hand tight should be sufficient to achieve a seal.

Hose washers are supplied and must be used.

ALLOW THE SHOWER HOSE TO HANG DOWN TO ALLOW THE WATER TO DISCHARGE SAFELY TO WASTE

AND OPEN THE ON/OFF CONTROL SO THAT THE WATER CAN GRAVITATE INTO THE PUMP TO PROVIDE

INITIAL PRIMING. WHEN WATER SHOWS, TURN THE CONTROL OFF.

If the water will not gravitate, fully open the on/off control; hold the hose higher than the Aquastream

Thermo unit and pour in clean water to prime the pump. When the water overflows, turn the controls off.

CHECK THE INSTALLATION FOR LEAKS.

Temperature limit stops

For additional safety, for example when the very young or elderly people will be using the shower, the

Aquastream Thermo incorporates a temperature limiting device enabling you to set minimum and maximum

temperature adjustment if required. We recommend the MAXIMUM outlet temperature is set to 46˚C.

Temperature adjustment is limited by inserting the limiting pins provided into the small holes in the face of

the cartridge as illustrated in step 4.

ELECTRICAL SUPPLY TO THE AQUASTREAM SYSTEM MUST BE ISOLATED BEFORE CARRYING OUT THE FOL-

LOWING OPERATIONS.

1. Remove the on/off control knob and temperature lever as outlined in steps 3 & 4.

2. Remove the front casing as outlined in step 4.

3. Refit one of the temperature lever screws into the top threaded hole in the temperature adaptor ring,

about 4 turns should be sufficient.

4. To set the maximum desired temperature, insert a limit pin into the mid-position hole in the upper set of

holes as indicated.

5. Using the temperature control lever screw to assist purchase turn the adaptor

ring clockwise until a stop is reached. Avoid exerting any pressure on the

microswitch assembly during this operation.

6. Turn the shower on by holding the on/off control loosely in place. Remove the

control by turning anticlockwise. Check that the water is now flowing at the

maximum desired temperature. Refit the control and turn the shower off.

7. If the flow is below the desired temperature, the limit pin will need to be

repositioned in a higher hole and the temperature control moved to the new stop position. Check the flow

temperature and repeat until correct.

8. If the minimum temperature setting is not required, proceed to step 10.

9. To set the minimum temperature, use the lower set of holes and proceed as above.

10.When the desired maximum and minimum temperature stops have been set, turn the temperature control

ring to the vertical position and remove the temperature fixing screw. Snap off the pins by levering

outwards and replace the front casing as outlined in step 19.

11.Refit the temperature control lever in the vertical position ensuring the fixing screws are hand tight only.

Refit the on/off knob ensuring the flat face on the on/off shaft is correctly aligned with the on/off knob

flat face and push fully home.

Mid-position maximum
temperature

Mid-position
minimum temperature

Aquastream Thermo thermostatic integral power shower

installation instuctions

Summary of Contents for Aquastream Thermo

Page 1: ...ctronic Equipment Producer Responsibility Regulation 2004 This product is outside the scope of the European Waste Electrical and Electronic Equipment Directive as interpreted within the UK In the UK t...

Page 2: ...Aquastream Thermo thermostatic integral power shower installation instuctions page 2 Aquastream Aquastream Thermostatic integral power shower...

Page 3: ...Aquastream Thermo thermostatic integral power shower installation instuctions page 3 Components...

Page 4: ...N FOLLOWING THE LATEST REVISION OF BS 7671 WIRING REGULATIONS AND CERTIFIED TO CURRENT BUILDING REGULATIONS The Aquastream Thermo is suitable for household use only This product is not intended for us...

Page 5: ...side of the cistern The casing must not be sited where it is subjected to continuous spray from the shower head Stored water capacities The minimum capacity of the cold storage cistern should not be l...

Page 6: ...y point for the low voltage cable and rear entry pipe work as necessary Remove the template and prepare suitable wall fixings and entry points as required 1 Site the transformer within 4 metres cable...

Page 7: ...entry concealed pipe work or exposed top or bottom entry pipe work Rear entry installation The 15mm supply pipes must emerge at 90 angles from the finished wall surface spaced at 65mm centres Ensurin...

Page 8: ...lower fixing screw and tighten the upper fixing screws 10 The pipe insertion depth measured from the point of entry into the top fitting is 160mm at 65mm centres Where plate copper tube is to be used...

Page 9: ...ed with a flat face which must be aligned before the knob is fitted Temporarily fit the on off control knob and rotate fully clockwise to the off position Turn the supplies on to check for leaks upstr...

Page 10: ...sformer assembly THE POWER SUPPLY TO THE AQUASTREAM THERMO MUST BE ISOLATED BEFORE REINSTATING THE DOMESTIC ELECTRICAL SUPPLY ALL COPPER PIPE WORK MUST BE CROSS BONDED AND CONNECTED TO A RELIABLE EART...

Page 11: ...itting into position into the top rail end body and secure the rail assembly to wall using the screws provided ensuring the rail and rail end bodies remain firmly engaged 27 Place the rail end covers...

Page 12: ...e lever screws into the top threaded hole in the temperature adaptor ring about 4 turns should be sufficient 4 To set the maximum desired temperature insert a limit pin into the mid position hole in t...

Page 13: ...aximum operating periods for this shower are 15mins on 45mins off Trouble shooting guide Check the fuse in the spur box or plug Check transformer cut out Symptom No power supply to the pump Pump fails...

Page 14: ...60010 Republic of Ireland 01 844 3212 Brochure Hotline 0800 652 3669 Website www aqualisa co uk Email enquiries aqualisa co uk Please note that calls may be recorded for training and quality purposes...

Reviews: