background image

• www.aquakingredlabel.nl • [email protected]

21

X

E

V

M

R

U

W

S

H

K1

I

F

K2

J

G

0-

7999

8000-

11999

12000

REPLACE

&

RESET

H

K1

I

F

K2

J

G

X

T

E

2

3

Summary of Contents for RED LABEL 2

Page 1: ... www aquakingredlabel nl info aquaking nl RedLabel drumfilterbasic handleiding manual model2 NL EN ...

Page 2: ... aquakingredlabel nl info aquaking nl 2 1 1 4 4 2 2 9 5 5 3 3 6 7 8 9 10 10 8 7 6 Drum LEGENDA UVC Spoelpomp Vuil afvoer Sproeiers 3 x Inlaat 110 mm Aandrijfmotor 2 x Uitlaat 110 mm Vlotter Nooddop Gravity ...

Page 3: ... www aquakingredlabel nl info aquaking nl 3 Besturingskast Aansluitkabel met koppeling ...

Page 4: ... www aquakingredlabel nl info aquaking nl 4 L M Q N O P Z L M Q N O P Z 1 Pomp gevoed Gravity ...

Page 5: ... www aquakingredlabel nl info aquaking nl 5 X E V M R U W S H K1 I F K2 J G 0 7999 8000 11999 12000 REPLACE RESET H K1 I F K2 J G X T E 2 3 ...

Page 6: ...gingen aan de UV te voorkomen De Uv moet te allen tijde onder water blijven Gravity gevoed systeem Het filter is geïnstalleerd op hetzelfde waterniveau als de vijver Door gebruik van een bodemafvoer kan het water afgevoerd worden naar het filtratie systeem Het filter systeem begint met het schoonmaken van het vijverwater De drum en sproeiers verdrijven het vuil uit het water wat daarna weggespoeld...

Page 7: ...ter minimum niveau 29 5 cm Hart van buis Beluchtingsbuis vuil afvoer Gravity Pomp gevoed 4 Belangrijk De Drum Filter Basic is een voorfilter systeem Een biologisch filter zoals de Red Label Moving Bed Filter moet aangesloten worden voordat het water retour de vijver ingaat ...

Page 8: ...um Filter Wij streven ernaar om u kwaliteits producten en professionele service te bieden Om ervoor te zorgen dat uw nieuwe aankoop goed en veilig functioneert raden wij u aan om deze handleiding te lezen alvorens het in gebruik te nemen Bewaar deze handleiding goed AquaKing Red Label Basic Drum Filter NL ...

Page 9: ...teren in een hoge UV C straling met een golflengte van precies 253 7 nm De hoge bestralingsdosis doodt vrijwel alle bacteriën virussen schimmels en levert aldus helder en schoon water Tevens zorgt de UV C straling ervoor dat het zeefpaneel schoongehouden wordt van zowel Bio film als algengroei dit resulteert in een optimale werkend apparaat voor schoon gezond water Door de intelligente elektronica...

Page 10: ...nt het apparaat volledig van het watercircuit te worden afgesloten Vóór ingebruikname het gehele apparaat netsnoer en stekker op schade controleren Bij beschadigingen mag het apparaat niet gebruikt worden Laat de beschadiging beoordelen door een dealer Het apparaat mag alleen ingeschakeld zijn als er voldoende waterdoorstroming is Kijk nooit direct in de lamp ter voorkoming van eventuele schade aa...

Page 11: ...amp F Houd rekening met de bereikbaarheid i v m onderhoud Zie ook Onderhoud Demontage Draai de borgmoer G los van het puntstuk Haal voorzichtig de UV C lamp F uit de verpakking en schuif deze in het kwartsglas I Steek de UV C lamp F in de lamphouder J en schuif het geheel voorzichtig verder in het kwartsglas I Zorg dat de O ringen K1 K2 altijd goed zitten Draai de borgmoer G handvast op het puntst...

Page 12: ...p lekkages Plaats het deksel L terug op de behuizing M Plaats nu de stekkers van de apparaten in de juiste stopcontacten op de controlbox N Zie aanduidingen op Besturingskast N zelf Plaats nu de stekker O van de Controlbox N in het daarvoor bestemde stopcontact en schakel het geheel aan door de switch P om te zetten Houd de drukknop Q 10 sec ingedrukt zodat de motor en hoge drukpomp worden geac ti...

Page 13: ... en controleer het geheel op slijtage 4 Draai nu de borgmoer G los en ontkoppel de UV C lamp F van de lamphouder J Wanneer nodig kunt u nu ook de lamp F vervangen zie punt 11 voor reset 5 Haal het kwartsglas I voorzichtig uit het puntstuk H 6 Het kwartsglas I kan met een hiervoor geschikt middel worden gereinigd Spoel het kwartsglas I na reiniging goed af voorkom krassen door een zachte doek te ge...

Page 14: ...er circulatiepomp uit Besturingskast halen en in apart stopcontact steken Noodvoorziening activeren Pomp gevoed opstelling Verbreek de stroomtoevoer en sluit het leidingwerk af Slipkoppeling aandraaimoment 65Nm De aandrijfas is voorzien van een slipkoppeling Bij een blokkering van de trommel wordt deze geactiveerd Aandraaimoment Instellen Motordeksel verwijderen Momentsleutel op M10 moer plaatsen ...

Page 15: ...Draai met de hand de trommel R rond totdat de bevestigingsstrip U en slangklemmen V naar boven wijzen Ontkoppel de slangklemmen V Draai nu de schroeven W uit de bevestigingsstrip U Verwijder nu het zeefpaneel S en vervang het door een nieuwe Bevestig de slangklemmen V en bevestigigingsstrip U weer Controleer vervolgens of het geheel juist bevestigd is Leg de deksel terug op de behuizing M Plaats n...

Page 16: ...stel onder garantie veranderen aanpassen demonteren en opnieuw monteren door onjuist gebruik en niet volgens de gebruikersaanwijzing handleiding punten in acht nemen producten die niet bij een dealer zijn gekocht en of waarvan de fabrikant verwacht dat de producten van diefstal of verduistering afkomstig zijn zeefelementen bij drum filters Belangrijke opmerking Laat uw product niet bevriezen Veran...

Page 17: ...label nl info aquaking nl 17 Winkel stempel Aankoopdatum __ __ ____ Model Drum Filter Basic Model 2 Garantieperiode 2 jaar Vragen Neem contact op met Red Label AquaKing info aquaking nl Aankoopbewijs Garantiebewijs NL ...

Page 18: ...akingredlabel nl info aquaking nl 18 1 1 4 4 2 2 9 5 5 3 3 6 7 8 9 10 10 8 7 6 Drum LEGEND UVC High pressure pump Drainage Sprayers 3 x Inlet 110 mm Drive motor 2 x Outlet 110 mm Ballast Emergency caps Gravity ...

Page 19: ... www aquakingredlabel nl info aquaking nl 19 Controller Box Connecting cables ...

Page 20: ... www aquakingredlabel nl info aquaking nl 20 L M Q N O P Z L M Q N O P Z 1 Pump fed Gravity ...

Page 21: ... www aquakingredlabel nl info aquaking nl 21 X E V M R U W S H K1 I F K2 J G 0 7999 8000 11999 12000 REPLACE RESET H K1 I F K2 J G X T E 2 3 ...

Page 22: ...nstalled as indicated to prevent damage to the UV unit The UV unit must be submerged at all times Gravity fed system The filter is installed at the same height as the pond water levels By placing a bottom drain in the pond the pond water is drained into the filtration system The filter begins with filtering the pond water The Sprayers and turning drum expel the dirt and grime from the pond water w...

Page 23: ...UV Vlotter minimum niveau 29 5 cm Hart van buis Beluchtingsbuis vuil afvoer Gravity Pump fed 4 Important The Drum Filter Basic is a pre filter system A biological filter such as Red Label Moving Bed must be installed connected before the water is returned to the pond ...

Page 24: ...asic Drum Filter We strive to offer you quality products and professional service In order to ensure that your new purchase functions properly and safely we advise you to read this manual thoroughly before usage Keep this manual safe for future reference AquaKing Red Label Basic Drum Filter EN ...

Page 25: ...lows in a higher doses of UV C radiation The radiation has a measured wavelength of 253 7 nM Due to this high dosage practically all bacteria viruses and fungi are obliterated as well as keeping the screen clean from bio film and algae growth The pond water is thus cleaner and healthier as a result Thanks to the incorporated intelligent electronics the UV C unit will indicate when the UV lamp is n...

Page 26: ...heck the entire product including cables and included accessories prior to usage Do not use the filter if there appears to be damage to any part of the product The damage should first be assessed by your dealer The filter system should only ever be switched on when sufficient water is flowing Never look directly at the UV lamp UV light can be hazardous to skin and eyes and can cause bodily harm Do...

Page 27: ...uring installation see also Maintenance Disassembly 1 Loosen the locking nut G from the adapter 2 Carefully remove the UV C lamp F from the packaging and slide it into the quartz glass I 3 Insert the UV C lamp F into the lamp holder J and carefully push the entirety into the quartz glass I Ensure the O rings K1 K2 always sit correctly 4 Tighten the locking nut G back onto the adapter H by hand EN ...

Page 28: ...ping hoses and connections for leakages Insert the plugs of the devices into the appropriate sockets on the control box N See indications on Controller Box N Insert the plug O of the Controller Box N into the appropriate socket and turn it on at the switch P Hold the push button Q in for 10 seconds so that the motor and high pressure pump are activated After around 20 30 minutes the rinsing cycle ...

Page 29: ...m the unit s housing 3 Rotate the drum by hand checking for wear and tear on the drum mesh 4 Loosen the lock nut adaptor and disconnect the UV C lamp F from the unit housing J 5 Carefully remove the quarts glass 6 The quarts glass I can be cleaned with a suitable cleaning agent Rinse the quarts glass I thoroughly after cleaning avoid scratching the glass by using a soft cloth 7 Once the quarts gla...

Page 30: ...circulation pump from the Controller Box and insert it into a separate socket Emergency action on a pump fed system Disconnect the power supply and close all piping off Slip coupling torque 65Nm The drive shaft is fitted with a slip coupling When the drum is blocked for any reason it is activated Setting the torque 1 Remove the motor cover 2 Place torque wrench on M10 nut which is on the shaft 3 H...

Page 31: ...e filter can be drained Rotate the drum R until the fastening strip U and hose clamps V are facing upward Loosen the hose clamps V Unscrew the screws W from the fastening strip U The mesh should now be loose can be replaced Refasten the fastening strip U with the screws W Refasten the hose clamps V Check that all is tighten and secured Place the filter lid M back on the filter Reconnect the power ...

Page 32: ...the following cases Any alterations adjustments dissembling and reassembling of the filter and parts without explicit permission from AquaKing Incompetent and negligent usage without adhering to this manual Products that have not been purchased from a dealer and or products that have been attained illegally Mesh elements from drum filters Important note Do not allow the filter to freeze Do not mod...

Page 33: ...dlabel nl info aquaking nl 33 Shop stamp Date of purchase __ __ ____ Model Drum Filter Basic Model 2 Warranty 2 years Questions Contact your dealer or Red Label AquaKing info aquaking nl Proof of Purchase Warranty EN ...

Page 34: ...label nl info aquaking nl Zijn er onduidelijkheden neem dan te allen tijde contact op met uw Red Label dealer Wij wensen u veel plezier met uw AquaKing Red Label series product handleiding manual drumfilterbasic model2 ...

Reviews: