background image

3

11.  If the equipment starts to vibrate abnormally, 

        STOP the motor and check immediately for 

        the cause. Vibration is generally an indication 
        of trouble.

Fogging Precautions

DANGER

A motionless atomizer may 

appear safe, but its blade 

could suddenly begin high-

speed rotation without 

warning as a result of 

control programming.

When the ORSM is automated by controls, 

warning signs should be posted near the high-

speed equipment.

Disconnect and lock out power source to inspect 

or service the unit.

G

ENERAL

 S

AFETY

Since the mobile ORSM uses high-speed 

components to atomize liquids, the following safety 

precautions must be observed at all times:

1.  Read all manuals included 

     with this product. Be familiar 

     with the product and controls.
2.  The ORSM is intended to be 

     used on level ground. Test for stability before 

     operation.
3.  Follow United States Environmental Protection 

     Agency (EPA) guidelines and regulations when 

     fogging chemical solutions.
4.  Follow all local electrical and safety codes 

     as well as the United States National  

 

     Electrical Codes (NEC) and Occupational  Safety  

     and Health Act (OSHA).
5.  Only persons well acquainted with these 

     rules of safe operation should be allowed to 

     use the atomizer.
6.  Keep visitors away and NEVER allow children in 

     the work area.
7.  Use of an extension cord for the ORSM is 

     not recommended. If necessary, refer to 

     the A.W.G  chart in the following section or 

     consult a  certified electrician.
8.  Before each use, inspect blade assembly 

     and electrical components for signs of damage, 

     deterioration, weakness or leakage. Repair or 

     replace defective items before using.
9.  Check all fasteners at frequent intervals for 

     proper tightness.
10.  Keep fingers away from a running unit; 

        fast moving and hot parts will cause injury 

        and/or burns.

MOTORS, ELECTRICAL EQUIPMENT AND 

CONTROLS CAN CAUSE ELECTRICAL 

ARCS THAT WILL IGNITE FLAMMABLE 

LIQUID OR GAS. NEVER OPERATE OR 

REPAIR IN OR NEAR FLAMMABLE LIQUID OR GAS. 

NEVER STORE FLAMMABLE LIQUIDS OR GASES IN THE 

VICINITY OF THE ATOMIZER.

POTENTIALLY HAZARDOUS

CHEMICAL VAPORS

12.  Avoid exposure to  

 

 

        hazardous chemicals. Wear a 

        respirator and protective  

 

        clothing - goggles, gloves, long 

        sleeves and pants, etc.
13.  Read and understand all directions and safety 

        precautions before operating ORSM. Follow all 

        E.P.A. guidelines for chemical use.
14. 

NO

 humans or animals should be in the area 

        during chemical/pesticide application.

        SERIOUS INJURY OR DEATH COULD OCCUR!
15.  Follow chemical manufacturer's  

 

        instructions regarding length of restricted 

        entry interval 

(REI)

NEVER OPERATE ORSM 

WITHOUT THE SAFETY GUARD 

IN PLACE UNLESS THE UNIT IS RAISED SEVEN FEET 

ABOVE WORKING HEIGHT.

WARNING

WARNING

DANGER

HIGH-SPEED ROTATION

Summary of Contents for SE-ORSM-1500

Page 1: ...XE ORSM MODEL o ORSM 1000 o ORSM 1500 Read Understand Retain for Future Reference XE MOBILE ATOMIZER USER S MANUAL AND OPERATING INSTRUCTIONS OPERATOR S MANUAL NOTICE UL and CSA Electrical Components...

Page 2: ...or problems or damages resulting from misuse SAFETY GUIDELINES This manual contains very important information This information will help ensure SAFETY and PREVENT EQUIPMENT PROBLEMS Use these symbols...

Page 3: ...w children in the work area 7 Use of an extension cord for the ORSM is not recommended If necessary refer to the A W G chart in the following section or consult a certified electrician 8 Before each u...

Page 4: ...E ONLY AWG American Wire Gauge Voltage 25 to 50 ft 50 to 100 ft 115 14 AWG 12 AWG 230 16 AWG 14 AWG Fig 12 ELECTRICAL GROUND FAULT RECEPTACLES ARE RECOMMENDED AND MAY BE REQUIRED BY LOCAL AND OR NATIO...

Page 5: ...See below On Off Pumps Connect unit s plumbing directly to a metering pump with 3 8 tube fitting provided This provides a way to feed chemical concentrate to the ORSM TESTING AND EVALUATION Turn on th...

Page 6: ...t the bottom of the fan housing See Fig 5 Use a measuring cup and turn on only the feed pump for a 60 second interval while catching the water from the feed tube Multiply ounces of water by 60 and the...

Page 7: ...rapped air If the problem persists check your pre set flow rate valve refer to page 6 Factory Pre set Flow Valve The ORSM will automatically prime the feed pump but if the pre set flow rate valve is i...

Page 8: ...l Noise It is normal to hear a slight rattling noise at start up and shut down This is caused by the tip of the liquid feed tube entering the center of the fan blade assembly reservoir 6 Fan Motor Bec...

Page 9: ...nut SST 4 43 11 16 x 1 1 4 flat washer SST 1 44 Drain tubing 3 45 Liquid tight cord fitting 2 46 Key 1 52 1 4 20 x 3 4 HH bolt SST 4 54 1 4 20 x 3 8 button head cap screw 6 56 5 16 18 x 3 4 HH bolt SS...

Page 10: ...w of motor Side of top pivot plate Rear of Housing Power supply in from on off switch Power supply out to pump 8 13 14 15 16 52 600 L 117 54 20 344 46 58 56 45 45 43 8 39 44 32 58 57 56 57 116 349 403...

Page 11: ...60 61 84 45 71 72 65 65 295 295 65 65 84 45 198 67 65 Tank s Wall Inside Tank ORSM TANK EXPLODED VIEW 232 207 86 69 69 75 171 173 143 3 8 tube fitting provided for optional connection to metering pump...

Page 12: ...1 84 3 4 M socket x 1 2 F NPT Bushing 2 86 6 32 x 1 2 oval slotted screw 6 93 Hose connector gasket 1 94 Hose connector 1 96 Gasket 2 97 Float valve 1 98 Stem 1 99 Float 1 111 Axle SST 1 126 1 4 lock...

Page 13: ...he blades about once a year or whenever a film of calcium or mineral deposits is visible While cleaning inspect for irregularities or hairline cracks and replace as necessary 5 Storage Protect your mo...

Page 14: ...ent lack of maintenance or unauthorized repairs or alterations which affect the machine s performance or reliability LIMITATIONS OF LIABILITY TO THE EXTENT ALLOWABLE UNDER APPLICABLE LAW JAYBIRD MANUF...