ROUBLESHOOTING

BEFORE INSPECTION AND/OR SERVICE

DISCONNECT AND LOCK OUT POWER SOURCE.

WARNING

1.  Poor/Inconsistent Fogging Output

       A.) 

Inconsistent or spotty chemical coverage usually occurs because the fog volume output is 

        

too high. Ideally, fog will disappear when fogging at rates near 3 GPH. To check for fog 

        

volume output, refer to Maximum Pre-set Flow Rate (See 

Page 6

). 

      

B.)

  Ensure the SST liquid feed tube is properly inserted 1/4" into the center of the fan blade 

        

assembly.

       C.)

  Reservoir may be clogged. Fluid entering a clogged reservoir will spill out of the center 

        

bearing instead of entering the passageways of the fan blades. To clean, remove the 

        

blade assembly from the motor shaft and totally disassemble. Next, flush the reservoir 

        

under a sink, making sure the passageways are cleared. Check and clear

        

the passageways for each individual blade as well. Reassemble and reattach.

       D.)

  It is possible for an air pocket to become caught within the plumbing.  If you think this 

        

is occurring, throttle the flow control valve to wide open a few times to expel any trapped 

        

air.  If the problem persists, check your pre-set flow rate valve (refer to page 6 Factory 

        

Pre-set Flow Valve). The ORSM will automatically prime the feed pump, but if the pre-set 

        

flow rate valve is in a fully closed position, the automatic priming will not occur, resulting 

        

in trapped air and poor/inconsistent fogging output. 

       E.)

  Consistency of fogging output greatly depends on the consistency of the cleaning 

        

procedures (See Page 10). Check strainer, plumbing, and inside of tank for dried 

        

sediment or clogs.

2.   Blades Rub Against Venturi

       A.)

  To make a horizontal adjustment, loosen the 4 bolts (Part #56) at the base of the main 

        

fan motor and shift motor side to side until centered. Retighten bolts.

       B.)

  To make a vertical adjustment, detach the housing by removing the 6 small bolts (Part 

        

#54). Next, loosen 4 bolts (Part #52) and make necessary adjustments. Retighten bolts 

        

and reattach housing.

3.   Fan and/or Pumps Do Not Operate

       Check voltage requirements on unit and electrical supply. Have a certified electrician check 

       for live receptacle, plug, power line and toggle switch. If the fan works but the pump does 

       not, look for any loose connections inside the main motor's junction box. If there are no loose 

       connections, the pump is probably damaged and should be replaced.

Summary of Contents for SE-ORSM-1500

Page 1: ...XE ORSM MODEL o ORSM 1000 o ORSM 1500 Read Understand Retain for Future Reference XE MOBILE ATOMIZER USER S MANUAL AND OPERATING INSTRUCTIONS OPERATOR S MANUAL NOTICE UL and CSA Electrical Components...

Page 2: ...or problems or damages resulting from misuse SAFETY GUIDELINES This manual contains very important information This information will help ensure SAFETY and PREVENT EQUIPMENT PROBLEMS Use these symbols...

Page 3: ...w children in the work area 7 Use of an extension cord for the ORSM is not recommended If necessary refer to the A W G chart in the following section or consult a certified electrician 8 Before each u...

Page 4: ...E ONLY AWG American Wire Gauge Voltage 25 to 50 ft 50 to 100 ft 115 14 AWG 12 AWG 230 16 AWG 14 AWG Fig 12 ELECTRICAL GROUND FAULT RECEPTACLES ARE RECOMMENDED AND MAY BE REQUIRED BY LOCAL AND OR NATIO...

Page 5: ...See below On Off Pumps Connect unit s plumbing directly to a metering pump with 3 8 tube fitting provided This provides a way to feed chemical concentrate to the ORSM TESTING AND EVALUATION Turn on th...

Page 6: ...t the bottom of the fan housing See Fig 5 Use a measuring cup and turn on only the feed pump for a 60 second interval while catching the water from the feed tube Multiply ounces of water by 60 and the...

Page 7: ...rapped air If the problem persists check your pre set flow rate valve refer to page 6 Factory Pre set Flow Valve The ORSM will automatically prime the feed pump but if the pre set flow rate valve is i...

Page 8: ...l Noise It is normal to hear a slight rattling noise at start up and shut down This is caused by the tip of the liquid feed tube entering the center of the fan blade assembly reservoir 6 Fan Motor Bec...

Page 9: ...nut SST 4 43 11 16 x 1 1 4 flat washer SST 1 44 Drain tubing 3 45 Liquid tight cord fitting 2 46 Key 1 52 1 4 20 x 3 4 HH bolt SST 4 54 1 4 20 x 3 8 button head cap screw 6 56 5 16 18 x 3 4 HH bolt SS...

Page 10: ...w of motor Side of top pivot plate Rear of Housing Power supply in from on off switch Power supply out to pump 8 13 14 15 16 52 600 L 117 54 20 344 46 58 56 45 45 43 8 39 44 32 58 57 56 57 116 349 403...

Page 11: ...60 61 84 45 71 72 65 65 295 295 65 65 84 45 198 67 65 Tank s Wall Inside Tank ORSM TANK EXPLODED VIEW 232 207 86 69 69 75 171 173 143 3 8 tube fitting provided for optional connection to metering pump...

Page 12: ...1 84 3 4 M socket x 1 2 F NPT Bushing 2 86 6 32 x 1 2 oval slotted screw 6 93 Hose connector gasket 1 94 Hose connector 1 96 Gasket 2 97 Float valve 1 98 Stem 1 99 Float 1 111 Axle SST 1 126 1 4 lock...

Page 13: ...he blades about once a year or whenever a film of calcium or mineral deposits is visible While cleaning inspect for irregularities or hairline cracks and replace as necessary 5 Storage Protect your mo...

Page 14: ...ent lack of maintenance or unauthorized repairs or alterations which affect the machine s performance or reliability LIMITATIONS OF LIABILITY TO THE EXTENT ALLOWABLE UNDER APPLICABLE LAW JAYBIRD MANUF...

Reviews: