RE208_Hardwire_to_Honeywell-Compat_Translator.doc
Page 1 of 4
5/25/2011
www.ResolutionProducts.com
Wireless
Security
Solutions
RE208 Hardwire-to-Honeywell
®
Wireless Translator™
Features
•
Converts hardwire zones into Honeywell-compatible wireless signals.
•
8 Hardwire loops with end-of-line resistor detection.
•
Unique wireless ID for each zone, plus 1 for main device.
•
Transmit diversity for long reliable range.
•
PIR powering (via external supply).
•
3 year operation on batteries (contacts only).
•
Complete supervision of zone tampers and low battery.
Key Instructions
•
Use with normally closed contacts in-line with 4.7 K-ohms end-of-line resistors.
•
Not for use with life safety devices, such as Smoke or CO sensors.
•
External supply requirements (wall-AC): 12V DC at least 50 mA.
•
PIR & Glassbreak (powered devices) usage:
4-wire devices only. Not for use with 2-wire powered devices.
2 AA back-up batteries will drive contacts only, and cannot drive a PIR.
Under external supply failure, the PIR/Glass would likely alarm.
If using PIR/Glass, we recommend using 12V DC, 24-hour back-up supply.
If using old panel 12V DC supply, verify operation and old battery.
•
Enrolling:
Hardwire zones (labeled “Loops” on the circuit board terminals):
•
Hardwire zones are enrolled into Honeywell system using the RF Learning
tripping enrollment mode.
•
Input Type: 3 (Supervised RF), Loop: 2
•
When prompted, open/close each zone twice
(fault/restore/fault/restore) to enroll the serial number.
Translator itself. Trouble supervision of the Translator itself is recommended;
Assign the Translator to a zone for sending check-in supervisories, cover
tamper and low battery.
•
Zone Type: 8 (24 hour Aux) – When cover opened: “fault” when system
not armed, “alarm” when armed.
•
Input Type: 3 (Supervised RF), Loop: 4
•
When prompted, toggle the tamper switch to enroll the serial number.
Operation
•
8 Hardwire 4.7K-ohm Zones – transmit 8 unique wireless IDs:
Alarm on open circuit. Tamper on short circuit.
Supervisories, every hour for each zone.
RE208_Hardwire_to_Honeywell-Compat_Translator.doc
Page 2 of 4
5/25/2011
www.ResolutionProducts.com
4.7K
Contact
Closed Normally
Open in Alarm
Loop
x
PIR
To Enroll zone,
perform 2 open/close
sequences
12V DC
AA Backup
batteries will NOT
power PIR
•
Translator Main Zone wireless transmission (9
th
unique ID):
Tamper, when cover opened.
Low battery, when either low AA batteries, OR loss of 12V DC external.
Supervisory every hour.
•
How ID’s work: If the Translator Main Zone is XXX-YYY0, then the Zone 1’s ID is
XXX-YYY1, and Zone 2’s ID is XXX-YYY2, etc.
•
LED Operation
Green LED: On if AC power present.
Red LED:
When 12V DC is present: “Blinks” on transmit to panel;
“on” if device tamper or device low battery.
•
Application Diagram
•
Connection Diagram
New Wireless
System
Existing Hardwire Sensors
New
Self-Contained System in
public area
Old Hardwire Panel Mounted
in utility area
New System’s wireless
language