RE208  Hardwire-to-Honeywell

®

 Wireless Translator™ 

 

Features 

 

Converts hardwire zones into Honeywell-compatible wireless signals. 

 

8 Hardwire loops with end-of-line resistor detection. 

 

Unique wireless ID for each zone, plus 1 for main device. 

 

Transmit diversity for long reliable range. 

 

PIR powering (via external supply). 

 

3 year operation on batteries (contacts only). 

 

Complete supervision of zone tampers and low battery. 

 

Key Instructions 

 

Use with normally closed contacts in-line with 4.7 K-ohms end-of-line resistors. 

 

Not for use with life safety devices, such as Smoke or CO sensors. 

 

External supply requirements (wall-AC):  12V DC at least 50 mA. 

 

PIR & Glassbreak (powered devices) usage:   

 

4-wire devices only.  Not for use with 2-wire powered devices. 

 

2 AA back-up batteries will drive contacts only, and cannot drive a PIR. 

 

Under external supply failure, the PIR/Glass would likely alarm. 

 

If using PIR/Glass, we recommend using 12V DC, 24-hour back-up supply. 

 

If using old panel 12V DC supply, verify operation and old battery. 

 

Enrolling: 

 

Hardwire zones (labeled “Loops” on the circuit board terminals): 

 

Hardwire zones are enrolled into Honeywell system using the RF Learning 
tripping enrollment mode.   

 

Input Type: 3 (Supervised RF), Loop: 2 

 

When prompted, open/close each zone twice 
(fault/restore/fault/restore) to enroll the serial number.   

 

Translator itself.  Trouble supervision of the Translator itself is recommended;  
Assign the Translator to a zone for sending check-in supervisories, cover 
tamper and low battery.   

 

Zone Type: 8 (24 hour Aux) – When cover opened: “fault” when system 
not armed, “alarm” when armed. 

 

Input Type: 3 (Supervised RF), Loop: 4 

 

When prompted, toggle the tamper switch to enroll the serial number. 

 

Operation 

 

8 Hardwire 4.7K-ohm Zones – transmit 8 unique wireless IDs: 

Alarm on open circuit. Tamper on short circuit. 
Supervisories, every hour for each zone. 

RE208_Hardwire_to_Honeywell-Compat_Translator.doc 

Page 2 of 4 

5/25/2011 

www.ResolutionProducts.com

 

4.7K

Contact

Closed Normally

Open in Alarm

Loop

x

PIR

To Enroll zone, 

perform 2 open/close 

sequences

12V DC

 AA Backup 

batteries will NOT 

power PIR

 

 

Translator Main Zone wireless transmission (9

th

 unique ID): 

Tamper, when cover opened. 
Low battery, when either low AA batteries, OR loss of 12V DC external. 
Supervisory every hour. 

 

 

How ID’s work:  If the Translator Main Zone is XXX-YYY0, then the Zone 1’s ID is 
XXX-YYY1, and Zone 2’s ID is XXX-YYY2, etc. 
 

 

LED Operation 

Green LED:  On if AC power present. 
Red LED: 

When 12V DC is present: “Blinks” on transmit to panel; 
“on” if device tamper or device low battery. 

 

 

Application Diagram 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 

Connection Diagram 

 
 

 

New Wireless 
System 

 

Existing Hardwire Sensors 

 

New  
Self-Contained System in 
public area 

 

Old Hardwire Panel Mounted 

in utility area

 

New System’s wireless 

language 

 