7
STANDARD MONITORING SYSTEMS
:
Fig. A
S
TANDARD
M
ONITORING
S
YSTEM
C
ONTROL
P
ANEL ON AN
O
PTIMA
HX
Elements to identify the HX Standard Monitoring
System are:
1.
UV LED Operational Display
2.
Main Power Switch
3.
Running Time Meter
4.
Integrated Monitoring System
5.
Lamps Operational -
optional
6.
Lamp Out Alert -
optional
Fig. B
S
TANDARD
C
ONTROL
P
ANEL
UV Operational Display:
FOR
NEMA R
ATED
C
ABINET
To verify the status of the UV lamps, the LED display gives the operator a visual
indication of the lamp status. When the UV lamp is “ON”, the LED will illuminate.
When “OFF”, the LED will not illuminate. Should any UV lamp fail to operate, the
corresponding LED light will automatically turn “OFF”.
Each UV lamp is numbered at the end of the treatment chamber and the
corresponding LED light carries the same number on the display panel.
Main Power Switch:
The Main Power Switch isolates all electric power to the unit.
Running Time Meter:
Each of the UV units is furnished with a Running Time Meter that cannot be reset.
It is used to determine the number of hours on the equipment and for
maintenance. It is very important to record the running time hours and lamp
maintenance.
Lamps Operational & Lamp Out Alert:
For remote monitoring of the UV lamp status, the Lamp Out Alert option is
available. The printed circuit board continuously monitors the lamp status. When
one or more lamps are out, a SPDT contact is available for customer interfacing
during Lamp Out Condition. The contact will enable interfacing into a central
monitoring system (PLC, DCS, etc). During the lamp out fault condition, a visual
3
1
2
5
6
4
1
2
3
4
5
6