English
Operational log book
Note
In the case of an official inspection and during all customer ser-
vice activities, as the operator you are obliged to hand the oper-
ational log book over to the authorised persons.
Due to the more stringent environmental protection directives, as
the operator you are officially obliged to document the operation
and servicing of the BioSaver
®
/ WRB Bio in the form of an oper-
ational log book. A suitable operational log book is a folder that
must contain the following documents:
Approval certificate for the system
Drainage plan for the system
Safety data sheets for all cleaning agents that you use
Handover report for the system
Warranty conditions for the system
In addition to these basic documents, the operational log book is
also used for documenting all third-party inspection, service and
cleaning work performed on the system (duty of care). The corre-
sponding forms are attached:
1. Add a new standard form at the start of each month and enter
the month and year on this form.
2. Describe all inspection, service and cleaning work performed,
specifying the day and persons performing the work
3. Record all results of waste water analyses of the treated waste
water, including those performed within the scope of the Ger-
man Own Inspection Directive (EkVO).
4. File all disposal certificates provided by the company dispos-
ing of the sludge trap contents.
5. File all service work and work performed by customer service
technicians or work performed within the scope of a service
contract in this book.
Store this operational log book in an easily accessible location so
that your employees can always keep it up to date.
Control cabinet air supply
Note
The control air supply to the control cabinet must be ensured at
all times, day and night.
A permanent supply of control air to the control cabinet is impor-
tant to ensure a correctly functioning system. If the control air is
provided via the company-internal compressed air supply then
ensure that this supply remains available at night, on Sundays
and public holidays.
Operation via the touch screen
The display is located on the front of the control cabinet. The display
is used for controlling the system and displaying system data.
Main window display ("Home")
The display is operated by touching the buttons. The main win-
dow ("Home") is shown on the display by default.
1
"Manufacturer" button: Change to the "Manufacturer Code"
screen
2
"Service" button: Change to the "Service Code" screen
3
"QR-Code" display of the service number (the service tele-
phone number can be entered by the service technician dur-
ing initial commissioning)
4
"Time" button / display
5
"Date" button / display
6
"System manufacturer" button
7
Display field: "Last Information" appears in yellow / "Last Er-
ror" appears in red
8
"System Diagram" button: Change to the "System Diagram"
screen
9
"Error query" button: Message blinks red
10
"Information query" button: Message blinks yellow
11
"Acoustic Warning" button: Change to the "Error /Information
Message" screen
12
"Service" button: Change to the "Service" screen
"Date" / "Time" screen
On touching the "Date" or "Time" button in the main window, a
keyboard field is displayed for entering the date or time.
1
"Date" display / entry
2
"Time" display / entry
3
"Set Date Time" button: Accepts the date or time
"Date" / "Time" keyboard field screen
The keyboard field is used for entering the date or time.
"0"-"9" buttons: Enter the date or time. The entry is shown in
the display field
"Clr" button: Delete the entry
"Enter" button: Confirm the entry
"Esc" button: Back to the Date / Time entry window
12
11
10
9
8
7
6
5
4
3
2
1
3
2
1