background image

Page - 10

Spa Only, No Valves, Jandy VS

This preset configures the heat pump as
follows:

l

No valve actuators are configured.

l

A Jandy variable speed circulation pump is
configured.

l

A pool schedule is configured (Everyday
from 8:00 am to 6:00 pm)

When pressed, the "Pool/Spa" button will display with two choices.

1. Spa - With an initial timer of 2 hours at 104° F.

2. Spa - With an initial timer of 2 hours at 96° F (

104° F with an installed OTA kit

).

3. Schedules

Spa Only, No Valves, Single Speed Circulation Pump

This preset configures the heat pump as
follows:

l

No valve actuators are configured.

l

A single speed circulation pump is
configured to use the relay "A" connection
point on the expansion board.

l

A pool schedule is configured (Everyday
from 8:00 am to 6:00 pm)

When pressed, the "Pool/Spa" button will display with two choices.

1. Spa - With an initial timer of 2 hours at 104° F.

2. Spa - With an initial timer of 2 hours at 96° F (

104° F with an installed OTA kit

).

3. Schedules

Summary of Contents for STK0247

Page 1: ...ore installation advice see the online installation and operation manual http www aquacal com wp content uploads manuals landingpage exp Expansion_Board_Upgrade_Manual htm Important Read this document before operating this product For additional product manuals and operation installation procedures please visit www AquaCal com LTP0168 REL B project rel 8 00 ...

Page 2: ......

Page 3: ...Table of Contents 1 Connections 1 2 Presets 3 3 Configuration 12 3 1 Create a Group 12 3 2 Create a Schedule 14 i ...

Page 4: ... to heed the following may result in damage to equipment l Failure to protect equipment against corrosive conditions will adversely affect the life of the equipment and will void equipment warranty PLEASE NOTE It is not necessary to connect an expansion board if the user only wishes to control an RS 485 equipped variable speed circulation pump Controlling actuators relays or a single speed circula...

Page 5: ...Follow all National Electric Codes NEC unless State or Local guidelines supersede 10 Reconnect wires leading to power control board 11 Attach device wires to the expansion board Figure 2 Available Ports l Circulation Pump l Port B RS 485 Connector Normally used for Variable Speed Circulation Pumps l Actuators l Port VA Return l Port VA Intake l Port VA Solar Optional l Relays l Relay A The default...

Page 6: ...h is not covered under factory warranties PLEASE NOTE l If the PoolSync external controller was used prior to upgrading the system all applicable heat pump presets will be shown l If a third party external controller was used prior to upgrading the system a factory reset will be required to see all presets See Factory Reset ALSO NOTE After using a preset any setting can be manually customized or f...

Page 7: ...peed circulation pump is configured l A pool schedule is configured Everyday from 8 00 am to 6 00 pm When pressed the Pool Spa button will display with three choices 1 Pool With an initial timer set for 48 hours at 85 F 2 Spa With an initial timer of 2 hours at 104 F 3 Spa With an initial timer of 2 hours at 96 F 104 F with an installed OTA kit 4 Schedules Pool Spa No Valves Jandy VS This preset c...

Page 8: ...at 104 F 3 Spa With an initial timer of 2 hours at 96 F 104 F with an installed OTA kit 4 Schedules Pool Spa Valves Pentair VS This preset configures the heat pump as follows l Two actuator valves are configured named intake on VA INTAKE and return on VA RETURN l A Pentair or Sta Rite variable speed circulation pump is configured l A pool schedule is configured Everyday from 8 00 am to 6 00 pm Whe...

Page 9: ... hours at 104 F 3 Spa With an initial timer of 2 hours at 96 F 104 F with an installed OTA kit 4 Schedules Pool Spa Valves Jandy VS This preset configures the heat pump as follows l Two actuator valves are configured named intake on VA INTAKE and return on VA RETURN l A Jandy variable speed circulation pump is configured l A pool schedule is configured Everyday from 8 00 am to 6 00 pm When pressed...

Page 10: ...ed OTA kit 4 Schedules Pool Only No Valves No Pump This preset configures the heat pump as follows l No valves actuators are configured l No circulation pump is configured l No schedules are configured When pressed the Pool Spa button will display with two choices 1 Pool With an initial timer set for 48 hours at 85 F 2 Schedules Without an active schedule the heat pump mode is initially set to OFF...

Page 11: ...configured l A Jandy variable speed circulation pump is configured l A pool schedule is configured Everyday from 8 00 am to 6 00 pm When pressed the Pool Spa button will display with two choices 1 Pool With an initial timer set for 48 hours at 85 F 2 Schedules Pool Only No Valves Single Speed This preset configures the heat pump as follows l No valve actuators are configured l A single speed circu...

Page 12: ...d circulation pump is configured l A pool schedule is configured Everyday from 8 00 am to 6 00 pm When pressed the Pool Spa button will display with two choices 1 Spa With an initial timer of 2 hours at 104 F 2 Spa With an initial timer of 2 hours at 96 F 104 F with an installed OTA kit 3 Schedules Spa Only No Valves Hayward VS This preset configures the heat pump as follows l No valve actuators a...

Page 13: ...timer of 2 hours at 96 F 104 F with an installed OTA kit 3 Schedules Spa Only No Valves Single Speed Circulation Pump This preset configures the heat pump as follows l No valve actuators are configured l A single speed circulation pump is configured to use the relay A connection point on the expansion board l A pool schedule is configured Everyday from 8 00 am to 6 00 pm When pressed the Pool Spa ...

Page 14: ...D AT THE POWER BREAKER Wait for 2 minutes after the shut down of equipment before servicing l Follow all National Electric Codes NEC and or State and Local guidelines Figure 3 USB Thumb Drive Port 1 Turn off power at heat pump s power disconnect 2 Wait two minutes for capacitors to discharge before proceeding 3 Remove heat pump electrical access panel 4 Insert thumb drive into the heat pump s USB ...

Page 15: ...s The example below shows a BACKYARD LIGHTS group being created manually Two devices will be set to an operating state of ON when the group is active l A pool light relay l A spa light relay PLEASE NOTE This section only describes the configuration of an already connected relay device To physically wire these types of devices to the heat pump see the heat pump s installation manual Enter Groups me...

Page 16: ...O ADD EQUIPMENT 11 USE ARROWS TO SELECT EQUIPMENT 12 ENTER TO SAVE 13 USE ARROWS TO DEVICE OPERATING STATE 14 ENTER TO SAVE 15 USE ARROWS TO ADD EQUIPMENT 16 PRESS ENTER TO ADD MORE EQUIPMENT 17 USE ARROWS TO SELECT EQUIPMENT 18 ENTER TO SAVE 19 USE ARROWS TO DEVICE OPERATING STATE 20 ENTER TO SAVE MENU TO EXIT PRESS HOLD TO STATUS ...

Page 17: ... menus then proceed IF UNIT IS ASLEEP SWIPE TO WAKE UP A PRESS MENU BUTTON B USE ARROWS TO SCHEDULES C PRESS ENTER 1 ARROWS TO GROUP TO SCHEDULE 2 ENTER TO EDIT 3 USE ARROWS TO THE PROGRAM TO SCHEDULE 1 4 4 ENTER TO EDIT 5 USE ARROWS TO EDIT DAYS 6 ENTER TO SAVE 7 USE ARROWS TO START TIME 8 ENTER TO EDIT 9 USE ARROWS TO CHANGE 10 ENTER TO SAVE 11 USE ARROWS TO END TIME 12 ENTER TO EDIT 13 USE ARRO...

Page 18: ...Page 15 MENU TO EXIT PRESS HOLD TO STATUS ...

Page 19: ......

Reviews: