PROGRAMMING AND OPERATION
36
Total Control Menus
(System configuration must indicate Total Control configuration and is automatically
detected when the electrical connections are made between the #75003 and #75001 systems)
Set pH overfeed
(Range: No pH overfeed - 120 minutes in 5 minute increments) (Used to stop the chlorine and acid feed if the pH
set point is not reached in the user programmed time.)
1.
Press MENU, press
∆
or
∇
until “
Maintenance menu
” is displayed, then press SELECT.
2.
Press
∆
or
∇
until “
pH overfeed
” is displayed, then press SELECT (No pH overfeed is the factory setting).
3.
Press
∆
or
∇
to the desired overfeed time setting, then press SELECT.
4.
Press
∆
or
∇
until “
End menu mode
” is displayed, then press SELECT.
Set pH min
(Used to set the lower limit of pH adjustment before a warning message is displayed)
1.
Press MENU, press
∆
or
∇
until “
Maintenance menu
” is displayed, then press SELECT.
2.
Press
∆
or
∇
until “
Set pH min
” is displayed, then press SELECT (6.5 is the factory setting).
3.
Press
∆
or
∇
to the desired pH min setting, then press SELECT.
4.
Press
∆
or
∇
until “
End menu mode
” is displayed, then press SELECT.
Set pH max
(Used to set the upper limit of pH adjustment before a warning message is displayed)
Note: For safety reasons, acid will not feed when measured above the programmed pH max.
1.
Press MENU, press
∆
or
∇
until “
Maintenance menu
” is displayed, then press SELECT.
2.
Press
∆
or
∇
until “
Set pH max
” is displayed, then press SELECT (8.0 is the factory setting).
3.
Press
∆
or
∇
to the desired pH max setting, then press SELECT.
4.
Press
∆
or
∇
until “
End menu mode
” is displayed, then press SELECT.
Calibrate pH
(Used to match the pH display of the Digital to the results of a reliable pH test kit)
1.
Press MENU, press
∆
or
∇
until “
Maintenance menu
” is displayed, then press SELECT.
2.
Press
∆
or
∇
until “
Calibrate pH
” is displayed, then press SELECT (the pH sensor measurement will be displayed).
3.
Press
∆
or
∇
to match a reliable pH test result, then press SELECT.
4.
Press
∆
or
∇
until “
End menu mode
” is displayed, then press SELECT.
Enable / Disable ORP
(Used to temporarily enable or disable the ORP control system, thus disabling the chlorine generation)
1.
Press MENU, press
∆
or
∇
until “
Maintenance menu
” is displayed, then press SELECT.
2.
Press
∆
or
∇
until “
Enable ORP or Disable ORP
” is displayed, then press SELECT.
•
if
“Enable ORP”
then the ORP sensor is disabled, press SELECT to enable the ORP sensor.
•
if
“Disable ORP”
then the ORP sensor is enabled, press SELECT to disable the ORP sensor.
3.
Press
∆
or
∇
until “
End menu mode
” is displayed, then press SELECT.
Set ORP overfeed (Range: No ORP overfeed - 120 minutes in 5 minute increments)
(Used to stop the chlorine and acid feed if
the ORP set point is not reached in the user programmed time.)
1.
Press MENU, press
∆
or
∇
until “
Maintenance menu
” is displayed, then press SELECT.
2.
Press
∆
or
∇
until “
ORP overfeed
” is displayed, then press SELECT (No ORP overfeed is the factory setting).
3.
Press
∆
or
∇
to the desired overfeed time setting, then press SELECT.
4.
Press
∆
or
∇
until “
End menu mode
” is displayed, then press SELECT.