SPECIFICATIONS
4
Specifications
#75003 Pool Pilot Digital Control unit
Input Power
230 Vac
1.5 amps
(Normal input configuration shipped from the factory)
115 Vac
3 amps
(Optional input configuration – jumper wire to convert included)
Dry Contact
5 mA typical Non-factory ORP input circuit (110Vac output require a Relay Kit – PN# 110-ORP)
Chlorine Output
SuperCell Type
Maximum Chlorine Output (# 75003 Control unit set on Cell Power 3)
SC-36
1.28 lbs/day (0.58 kg/day)
SC-48
1.56 lbs/day (0.71 kg/day)
SC-60
1.92 lbs/day (0.88 kg/day)
CC-15
2.50 lbs/day (1.14 kg/day) – Commercial Cell
Manifold Flow Requirements
Minimum Flow Rate
20 gallons per minute (gpm) (76 liters/minute (L/m))
Maximum Flow Rate
100 gallons per minute (gpm) (379 liters/minute (L/m))
Maximum Pressure
85 psi (as tested by NSF)
Pump/Auxiliary Relay Output
Voltage Input
Amps / HP max
115 Vac
30 amps / 1 HP
230 Vac
30 amps / 2.5 HP
Agency Approvals
•
ETL tested to conform to the following UL specifications:
o
UL1081 - Standard for Safety for Swimming Pool Pumps, Filters and Chlorinators
o
UL 1563 - Standard for Safety for Electric Spas, Equipment Assemblies, and Associated Equipment.
•
CAN/CSA-E335-1 - Safety of Household and Similar Electrical Appliances
#75001 Pool Pilot Pool Chemistry Control unit
pH Acid Feed Pump and Tank AC Input Power
#75004 120
Vac
1.7
amps
#75005 220
Vac
0.9 amps
#75006 230
Vac
0.9
amps
#75007 250
Vac
0.9
amps
#75008 Auxiliary Relay Kit
115 / 230 Vac Relay
30 amps max
Low Voltage Input Power
PCC Communication
Factory Low Voltage Interface Cable provided with #75001
#75008 pH Auxiliary Relay Kit
(Optional) Dedicated Factory Low Voltage Terminal
Flow Cell
Flow Sensor
Fail – Safe status
Maximum working pressure
50 psi
Summary of Contents for Pool Pilot 75003