PROGRAMMING AND OPERATION
34
MENUS
(For the Installer Menu, press and hold SELECT button for approximately 13 seconds to access this feature)
Calibrating the salt sensor.
Note: The unit has been calibrated at the factory and should not need further adjustments. In the event that the salt display does
not match on-site test results, follow these steps:
1.
Press MENU, press
∆
or
∇
until “
Maintenance menu
” is displayed, then press SELECT.
2.
Press
∆
or
∇
until “
Calibrate salt
” is displayed, then press SELECT.
3.
Press
∆
or
∇
until the number on the display matches the accurately measured pool sample, then press SELECT. The
maximum adjustment is ± 1000 ppm (1.0 g/l).
4.
Press
∆
or
∇
until “
End menu mode
” is displayed, then press SELECT.
Calibrating the temperature display to match another thermometer
(Used only when it is desired to match the display of the
Digital to another thermometer display)
1.
Press MENU, press
∆
or
∇
until “
Maintenance menu
” is displayed, then press SELECT.
2.
Press
∆
or
∇
until “
Calibrate temp.
” is displayed, then press SELECT.
3.
Press
∆
or
∇
to adjust temperature up or down to the desired temperature, then press SELECT. The maximum
adjustment is ± 6
o
F (± 3
o
C). (To maximize protection, only negative adjustments will be used to calculate freeze
protection temperature.)
4.
Press
∆
or
∇
until “
End menu mode
” is displayed, then press SELECT.
Program the pool volume.
(Must be programmed for the “salt amount needed” display to be accurate)
1.
Press MENU, press
∆
or
∇
until “
Installer menu
” is displayed, then press and hold SELECT for 13 seconds.
2.
Press
∆
or
∇
until “
Set pool volume
” is displayed, then press SELECT
(Factory setting is 15,000 gallons)
.
(The range is 500 to 127,500 gallons (1,000 to 226,000 liters)
3.
Press
∆
or
∇
until correct pool size is displayed, then press SELECT.
4.
Press
∆
or
∇
until “
End menu mode
” is displayed, then press SELECT.
Program the cell type.
(Must match the installed cell)
1.
Press MENU, press
∆
or
∇
until “
Installer menu
” is displayed, then press and hold SELECT for 13 seconds.
2.
Press
∆
or
∇
until “
Set cell type
” is displayed, then press SELECT
(Factory setting is SC-48)
.
3.
Press
∆
or
∇
until the correct SuperCell type is displayed “
SC-36, SC-48, SC-60, CC-15”,
then press SELECT.
4.
Press
∆
or
∇
until “
End menu mode
” is displayed, then press SELECT.
Changing the output cell power level
(See recommendations on pg. 29 for when to change cell power. Factory setting is Cell
Power 2)
1.
Press MENU, press
∆
or
∇
until “
Installer menu
” is displayed, then press and hold SELECT for 13 seconds.
2.
Press
∆
or
∇
until “
Set cell power
” is displayed, then press SELECT.
3.
Press
∆
or
∇
until desired level “
Cell power
1, 2 or 3
” is displayed, then press SELECT.
4.
Press
∆
or
∇
until “
End menu mode
” is displayed, then press SELECT.
Programming the Set relay 1 function
(Used when the Digital is used to control the main circulation pump or pH acid feed pump)
1.
Press MENU, press
∆
or
∇
until “
Installer menu
” is displayed, then press and hold SELECT for 13 seconds.
2.
Press
∆
or
∇
until “
Set Relay 1
” is displayed, then press SELECT (Relay not used is the factory setting).
3.
The display will show the current configuration;
Relay not used – pump is controlled by an external time clock, controller or switch
One-speed – single speed pump is wired and programmed to the Digital
Two-speed – two speed pump is wired and programmed to the Digital
Acid pump – only when the main pump is not controlled by the Digital and the pH control option is installed
4.
Press
∆
or
∇
until the desired configuration is reached, then press SELECT.
5.
Press
∆
or
∇
until “
End menu mode
” is displayed, then press SELECT.