background image

Page - 3

CONTROL PANEL OVERVIEW

User Display

PoolSync

TM

Label

Figure 1

Reset Button LED

Pressing this button will allow the PoolSync

TM

to be reset.

l

Blinking

: Indicates the PoolSync

TM

unit is Offline and not

connected to the network.

l

Fading

: Indicates the PoolSync

TM

is connected to the local home

router.

l

Solid:

Indicates the PoolSync

TM

is connected to the Cloud.

Service Mode Button LED

Indicates the unit is in Service Mode.

l

Blinking:

Indicates there may be a communication error.

l

Solid:

Indicates your system is being serviced and user control

is disabled.

Service Access and Setup Button LEDs

l

Fading:

This will allow a service technician to use the

PoolSync

TM

as an access point when setting up all PoolSync

TM

Ready equipment.

l

Solid:

Indicates the unit is in setup mode and ready to be

connected to the home network.

Summary of Contents for AutoPilot PoolSync

Page 1: ... is the Purchaser s property and is to remain with the equipment owner LTP0160 REV 2 0 Important This manual covers the installation and operation of the PoolSyncTM device Read this manual and product labels before installing or operating this equipment ...

Page 2: ......

Page 3: ...ervice Mode Button LED 3 Service Access and Setup Button LEDs 3 Installation Wiring to a PoolSyncTM Ready Device 4 ChlorSync Wiring 4 AquaCal Heat Pump Wiring 6 ChlorSync and AquaCal Heat Pump Combination 8 Downloading the PoolSyncTM App 11 11 11 Connect the PoolSyncTM to the WiFi Discover Connected Equipment Mounting the PoolSyncTM 11 Troubleshooting Troubleshooting 12 Reference FCC Compliance 13...

Page 4: ... or repair the PoolSyncTM will void the factory warranty SAFETY SIGNALS Throughout this manual safety signals are placed where particular attention is required WARNING Failure to heed the following may result in permanent injury or death CAUTION Failure to heed the following may result in equipment damage WARNING Failure to heed the following may result in permanent injury or death l RISK OF ELECT...

Page 5: ...vice that allows the user to view and control PoolSyncTM Ready devices via the PoolSyncTM iOS or Android app The controller device is connected to the PoolSyncTM Ready equipment by a four 4 wire connection using an RS485 protocol When paired with the PoolSyncTM device advanced functionality and control of the PoolSyncTM Ready equipment will be available The ChlorSync chlorinator l View current sal...

Page 6: ...id Indicates the PoolSyncTM is connected to the Cloud Service Mode Button LED Indicates the unit is in Service Mode l Blinking Indicates there may be a communication error l Solid Indicates your system is being serviced and user control is disabled Service Access and Setup Button LEDs l Fading This will allow a service technician to use the PoolSyncTM as an access point when setting up all PoolSyn...

Page 7: ...ur conductor cable that will connect to your PoolSyncTM Ready pool equipment The correct wiring sequence must be followed to ensure your unit will communicate with the PoolSyncTM Ready products ChlorSync Wiring 1 Turn off power to the ChlorSync unit 2 Remove the power center cover and the grommet in one of the available openings on the bottom of the box 3 Insert the strain relief provided with the...

Page 8: ... YEL or A l Green wire from PoolSyncTM to GRN or B l Red wire from PoolSyncTM to RED VDC or 10v PoolSyncTM Wiring Figure 2 ChlorSync Wiring Figure 3 Note Before mounting the PoolSyncTM verify WiFi reception See Mounting the PoolSyncTM on page 11 Signal strength guide l Good l Moderate l Poor ...

Page 9: ...fter the shut down of equipment before servicing l RISK OF ELECTRICAL SHOCK Only qualified professionals who are familiar with the swimming pool and spa safety standards should service this unit The installer must be familiar with service industry techniques AquaCal Heat Pump Wiring 1 Turn off all power to the heat pump Wait for 2 minutes after the shut down of equipment before removing panels 2 O...

Page 10: ...erify WiFi reception See Mounting the PoolSyncTM on page 11 CAUTION Failure to heed the following may result in equipment damage l Do not connect two RED wires in the same port This may cause damage to the equipment Damage resulting from improper wiring will void the unit s warranty l Failure to follow instructions may result in property damage The PoolSyncTM must be installed and operated as spec...

Page 11: ...wire to B l DO NOT attach a second red wire between the heat pump and the chlorinator This will cause damage to the equipment Secure open wire as per electrical code to prevent electrical shock l Note It is acceptable to double up two wires on the same four pin connector 4 Verify the wires are firmly held in place by gently pulling on the wire 5 Replace the connector onto the PCB header pins Be su...

Page 12: ...l DO NOT attach a second red wire between the heat pump and the chlorinator This will damage the equipment Secure open wire as per electrical code to prevent electrical shock l Note It is acceptable to double up two wires on the same four pin connector 3 Verify the wires are firmly held in place by gently pulling on the wire 4 Thread the other end of the wire through an available opening at the bo...

Page 13: ...Page 10 PoolSyncTM Connected to the ChlorSync Figure 7 PoolSyncTM Connected to the AquaCal Heater Figure 8 ...

Page 14: ...home network 7 When the PoolSyncTM is connected to the network you will be redirected to the Dashboard The newly configured equipment should be visible if you are on the same WiFi network Discover Connected Equipment Verify the pool equipment is connected to a power source and turned on The PoolSyncTM will automatically attempt to discover connected equipment after being setup This process can tak...

Page 15: ...inated On The PoolSyncTM Unit Confirm equipment is receiving power Verify all wires from the PoolSyncTM unit to the PoolSyncTM Ready equipment are properly seated and securely tightened Reset the PoolSyncTM unit by pushing the arrow button Confirm the transformer is wired correctly See the wiring diagram on the inside cover of the power center Restart the equipment connected to the PoolSyncTM devi...

Page 16: ...complies with part 15 of the FCC rules Operation is subject to the following conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation ...