Innovative purification solutions
www.aquablu.com
19
UV SYSTEM
Description:
304 Stainless Steel Ultraviolet Water Disinfection System
Applications:
Drinking water, food processing, medical and industrial etc.
Function:
Killing bacteria, viruses, molds and algae in water.
Power consumption: 8W-72W
Power supply:
110V or 220V 50/60Hz (12V on special request)
1. Reactor Chamber (304SS)
2. Quartz Tube
3. O-ring
4. O-ring
5. Open End Nut
6. Closed End Nut
7. UV Lamp
8. 4-pin Electrical Socket
9. Protective Cover
10. Electronic Ballast
Fig. 14 UV unit
UV INSTALLATION STEPS:
1.
Open the package to check all components are there: Reactor Chamber, UV Lamp,
Quartz Tube, O-ring, Electronic Ballast and Support.
2.
Make the Quartz Tube and UV Lamp clean before installation (clean with alcohol or
mild detergent). Wear soft non-abrasive gloves to prevent finger marks.
3.
Remove both Open and Closed End Nut from the Reactor Chamber.
4.
Install O-ring onto the open end of Quartz Tube (12mm from the edge).
5.
Insert the Quartz Tube into the Reactor Chamber.
6.
Install O-ring onto the closed end of Quartz Tube.
7.
Hand-tighten the Closed End Nut on the Reactor Chamber (closed end of Quartz
Tube). To protect the O-ring, do not over tighten.
8.
Hand-tighten the Open End Nut on the Reactor Chamber (open end of Quartz
Tube). To protect the O-ring, do not over tighten.
9.
Tightly connect the 4-pin Electrical Socket with the UV Lamp pins.
10.
Carefully insert the UV Lamp into the Quartz Tube through Open End Nut.
11.
Install the Protective Cap on the Open End Nut by hand.