times within 1 second.
6.
Let the faucet run for 2 minutes then close the faucet.
-end of changing the mineral cartridge -
MEMBRANE FILTER
The replacement intervals are dependent on the degree of water contamination and will typically
vary between one and two years. To keep track of the replacement intervals it is advised to scan
the NFC chip and let the aquablu App show you when to replace the filters. If suddenly the
replacement intervals significantly shorten, it is advised to contact your local dealer.
HOW TO REPLACE THE MEMBRANE FILTER INSERT
1.
Close off the feed water supply.
2.
Depressurize the system by opening the water faucet. A “low pressure” alarm will be given
by the system when the system is depressurized (indicated by a red light on the faucet and
red
single flash on the unit in combination with a quick sound from the purification unit).
3.
Close the faucet.
4.
Disconnect the electrical power supply to the purification unit.
5.
Move the purification unit as far as you piping allows out of the cabinet and prepare a
drip tray. Expect 0.5 liter of water coming out of the membrane vessel.
6.
The membrane filter is mounted in a stainless steel tube that is an integral part of the
purification unit frame.
7.
Access to the membrane is gained by first removing the round plastic outer cover on the
front of the purification unit by rotating it counter clock wise. Inside this plastic cover a
small key-wrench is placed, see figure 20 below.
Fig. 21: Removal of front cover and key-wrench
8.
After removing the plastic cover the stainless steel locking plate is visible. On the locking