3. 

Safety instruction

ATTENTION! To avoid injuries, property damage and harm user's health, third parties as well,  a user
ought to get knowing with  present instruction before installation and use  of the dispenser. Failure to
comply with    the requirements  of the instruction  may  result in  property damage  and harm user's
health, third parties.
This device dispenses water at a very high temperature  (with the heating function)!!! 
At the using of the dispenser it is necessary to follow basic precautionary actions that include:

1. Before using the device must be mounted correctly and installed in accordance with the present

instruction.

2. Installation of the device is possible only on solid, flat, horizontal surface.

3.

 Do not keep the device in the confined space. Moving the device from one place to another, do not
hold onto the taps. 

4.

4. Place the dispenser not closer than 20 cm far from a wall and ensure free air flow between a wall
and the device. 

5. 5. Use the device only with properly grounded outlet.

6.

6. Do not use extension cords.

7.

7. Always, during removing the cord from an outlet, grab the plastic base of the plug. Never yank on
the power cord. The plug of the power cord must be easily accessible after device installation.

8.

8. Do not use the device, if the power cord is frayed or has another damage. In case of a damage of
the power cord it must be changed by the manufacturer, its service agent or another qualified person.
It is prohibited to use the device with damaged power cord. 

9.

9. Beware of electric current, do not wet the cord, plug or other parts of the cooler in water or other
liquid. 

10. Before cleaning the device make sure it is unplugged.

11.

Do not leave the children near the dispenser with hot water without proper and direct supervision. 
Turn off the power to the cooler in case of possible uncontrolled use by children. The device can be
used  by  children aged  8 years  and   older   and  persons  with  limited physical,   sensory or mental
abilities, or in the absence of experience and knowledge, if they are under the control of the person
responsible for their safety, or have been instructed about the safe use of the device and realize the
dangers. Children must not play with the device. Cleaning and service must not be carried out by
children without supervision. 

12. Service must be carried out by only a certified technician.

13.

Warning

: do not damage the refrigerant circuits (in devices with compressor cooling).

14. Cleaning and technical service must be carried out by only a certified technician. Access to service

areas is permitted only for persons having necessary knowledge and experience.

15.

The device must be used at an ambient temperature from + 5°C to + 43°C. and an air humidity of not
more than 85%. 

16. The dispenser is not intended to installation out of rooms or in a room where water can get on the

device

17.

The themostat has been already adjusted. There is no need to try to adjust it on your own.
(devices with compressor cooling). 

Summary of Contents for YL1345S-B

Page 1: ...Operating manual Water dispenser Model YL1345S B YL1536S YL1442S Thoroughly read the instruction before use...

Page 2: ...rd and handing them over to recycling companies To preserve the environment this equipment uses refrigerant R134a hydrofluorocarbon which does not damage the ozone layer insignificantly affects the gr...

Page 3: ...erosol cans with flammable fuel etc Technical characteristics Model Productivity Power consumption Rated power W Rated voltage Rated frequency Hz Dimensions mm Life time years Hot wate r l h 85 C Cold...

Page 4: ...Parts name 1 Hot Water Button 2 Warm Water Button 3 Cold Water Button 4 Neck for setting bottle 5 Top cover 6 Heating Indicator 7 Cooling Indicator 8 Cold Water Faucet...

Page 5: ...hole 17 Condenser Model YL1536S Parts name 1 Neck for setting bottle 2 Top cover 3 Cold Water Button 4 Hot Water Button 5 Cooling Indicator 6 Heating Indicator 7 Power Indicator 8 Cold Water Faucet 9...

Page 6: ...n child safety lock 4 Cold Water Faucet 5 Hot Water Faucet 6 Water Drip Tray 7 Heating Switch 8 Cooling Switch 9 Night light switch LED 10 Power cord 11 Condenser 12 Drain hole Note 3 5 The device is...

Page 7: ...3 1 2 3 4 20 5 6 7 8 9 10 11 8 12 13 14 15 5 43 85 16 17...

Page 8: ...r its service agent or another qualified person It is prohibited to use the device with damaged power cord 9 9 Beware of electric current do not wet the cord plug or other parts of the cooler in water...

Page 9: ...4 220 240 50 60 ON 4 1 1 2 3 4 5 6 7 8 9 10 11 12 6 5 5 430 85 950 1 2 24 3...

Page 10: ......

Page 11: ...e the bottle to the lower compartment of the dispenser and close it Bottle replacing 9 Open the door of the dispenser 10 Pull an empty bottle out of the compartment 11 Remove the cork with the tube fr...

Page 12: ...ion for transportation it is necessary to provide a reliable fastening of the device which protects against horizontal and vertical movements of the device during transportation If you will need to di...

Page 13: ...6 1 2 3 4 5 6 45 7 4 8 3...

Page 14: ...ving 4 If you do not use the device for a long time turn it off unplug the power cord out of an outlet and drain the remaining water through the drain hole 5 Do not use organic cleaning agents It is s...

Page 15: ...Excessive hot water consumption The device is not connected to the power source Too little time to cool Repeat the operation in a few minutes Connect the device to the power source and turn on the hea...

Page 16: ...be installed 3 Fix the bracket to the floor with screws 4 Tighten the screws Model YL1536 S 1 2 Loosen a screw in the lower left or lower right corner as it s shown at the picture 3 Use a screw to fi...

Page 17: ...ere are at least 10 cm between the back of the device and a wall and there 10 cm of empty place for both sides 4 Fix the screw bracket to the rear right corner of the dispenser as it s shown at the pi...

Page 18: ...period 24 months The service center is located at 73 Rostov on Don Vavilova street 73 863 201 88 75 8 15 51 Moscow 8 aya street Sokolinoy Gory 15 15 korp 925 740 29 05 32 St Petersburg Polyustrovskiy...

Reviews: