10
AQUA ULTRAVIOLET 42371 AVENIDA ALVARADO, TEMECULA, CA 92590 TEL: 951-296-3480 FAX: 951-296-3490
VIPER SL SERIES INSTALLATION INSTRUCTIONS
Flow Switch
Assembly
2" Example
3" or 6" Example
When installing a 3" Viper or larger, the Flow Switch is not attached to the unit body and must be
installed in line before the unit.
Water Flow
Water
Flow
Water Flow
Water
Flow
OVERVIEW: This unit can only be installed horizontally, DO NOT install vertically.
Do not install at ground
level to prevent it from lying in standing water. Your system should be easily accessible and as close to the
filter as possible. Do not submerge.
1. MOUNTING: Make sure water flow direction corresponds with the arrow below.
2. WATER LINE CONNECTION: Glue union to your pipe making sure water flow matches the arrow's direction
below.
CAUTION: If there are no leaks, turn the pump off and continue to the ELECTRICAL INSTALLATION
on page 12. If your unit leaks turn to the next page for leak solutions.
WARNING: DO NOT CONTINUE UNTIL YOUR INSTALLATION PASSES THE
LEAK TEST
3. LEAK TESTING: Do not install lamp or electrical components yet. After all the connections have been made
and the glue dries, turn the pump on and run it for five minutes to check for leaks.
Summary of Contents for Viper SL 1200 Watt