Unplug system, turn pump off, and drain housing.
2.
Untwist E-Z twist top.
20
Please go to our web site at
www.aquauv.com
for the
“Replacing a Quartz Sleeve Video”.
6. Twist off the large nut (EZ Twist Top). This will release the Quartz Sleeve and the assembly will still be
intact.
7. Once the Quartz Sleeve assembly is removed, you will need to clean it with swimming pool muriatic
acid. This can be purchased at your local swimming pool supply or your hardware store.
CAUTION:
Be sure to follow all instructions from the muriatic acid manufacturer when using their product.
NOTE:
Due to the caustic nature of this substance, the following instructions should only be completed outdoors in a
well-ventilated area.
NOTE:
Lime Away or similar products may be used, however, they are not as effective as muriatic acid and may need to
be soaked over night or until film is lifted.
8.
Wear rubber gloves and use a soft cloth to wipe down the quartz sleeve with the muriatic acid.
9.
Once the sleeve has been cleaned, wet the wiper blade and the quartz sleeve.
10.
Push the rod completely into the unit and insert quartz sleeve assembly through the blade(s). Make sure
quartz sleeve is inserted in the seat at the bottom of the unit. Tighten EZ Twist cap. For illustration
SEE WIPER
MAINTENANCE
illustration #17 on page 18.
NOTE:
Do not use any type of abrasive substance on the quartz sleeve as it may scratch the quartz.
AQUA ULTRAVIOLET 42371 AVENIDA ALVARADO, TEMECULA, CA 92590 TEL: 951-296-3480 FAX: 951-296-3490
CLEANING THE QUARTZ SLEEVE CONTINUED:
INSTALLING A REPLACEMENT QUARTZ SLEEVE:
3. Untwist Quartz Cap. Push quartz sleeve up through E-Z Twist Top.
4.
Discard broken quartz sleeve and rubber seal.
5.
Re-install E-Z twist top without quartz sleeve. Slide quartz sleeve in housing with rubber seal already on quartz
sleeve. Be sure to center the quartz sleeve into the seat at the bottom of the unit.