HOUSING INSTALLATION INSTRUCTIONS
NOTE:
All units are quality tested from the factory. All units are rated up to 50 PSI.
INSTALLATION SUGGESTIONS (HORIZONTAL)
SL 100, SL 200 1 lamp and SL 800-1000 Watt Units:
Plumb the water going down into the sterilizer at the
end closest to the wiper rod and up out of the end clos-
est to the transformer. This will insure the chamber stays
full of water and the wiper rod(s) does not push out.
Plumb the water going in from the bottom and out
through the top. This will insure the chamber stays
full of water and th wiper rod(s) does not push out.
INSTALLATION SUGGESTIONS (VERTICAL)
Plumb the water going in the bottom of the sterilizer and
coming out of the top. This will insure the chamber stays
full of water and the wiper rod(s) does not push out.
The above are suggestions, if you choose to install your unit in any manner other than the suggested, you must
ensure that the pump is strong enough to completely fill the chamber. If the water flow does not fill the chamber
the wiper nut may dry out causing a leak, and if left unattended the chamber will overheat and cause irrevers-
ible damage that is not covered under warranty.
CAUTION:
In a vertical installation be careful not to drop the lamp down inside the unit, this can break the quartz sleeve.
The quartz sleeve is not warranted against breakage nor is any damage caused as a result of a broken quartz sleeve.
(SEE ILLUSTRATION ON PAGE 20.)
NOTE:
You can use mounting brackets or plumbers straps to attach your unit to a wall or firm surface.
WARNING:
Before mounting or installing your unit check the quartz sleeve(s). Do not try to install, mount or operate this
unit if the quartz sleeve(s) appears to be broken or cracked. If broken or cracked contact your dealer.
10
For all other units up
to 1000 Watts, either
port can be used as
the inlet or outlet in
a vertical installation.
SL 200 2 Lamp, SL 300, SL 400, and SL 600 Watt Units:
AQUA ULTRAVIOLET 42371 AVENIDA ALVARADO, TEMECULA, CA 92590 TEL: 951-296-3480 FAX: 951-296-3490
1. MOUNTING:
Mount your Aqua Ultraviolet system horizontally or vertically on a wall or above ground, on a
level and firm surface. Do not lay the system on the ground. Your system should be easily accessible and as
close to the filter as possible. Do not submerge. Remember to allow enough room to pull the wiper all the way
out. Below are Aqua Ultraviolets suggested installation instructions.