background image

 

10 

-  Stopping  the  unit: 

If you stop the unit, always close tap water supply. Never put a valve into 

pure water. If you run the unit automatically with a solenoid valve, switch the valve between pre-
filter and module. Take care that waste water and pure water can flow away freely. 
 

- Disconnection of the unit: 

If you want to disconnect the unit for a longer period than 6 weeks, 

you  should  add  AB  Aqua  Medic  disinfection  liquid  into  the  module  housing.  If  the  unit  is  started 
again, flush it for 15 to 20 minutes. We recommend flushing also after shorter periods of stopping, 
if no disinfection liquid has been used. 
 

- Storage:

 The unit has to be stored at temperatures above 0° C. Freezing would destroy the 

membrane. 
 

7. Warranty 

 

Should  any  defect  in  material  or  workmanship  be  found  within  twelve  months  of  the  date  of 
purchase  AB  Aqua  Medic  GmbH  undertakes  to  repair  or, at our option, replace the defective part 
free of charge – always provided the product has been installed correctly, is used for the purpose 
that was intended by us, is used in accordance with the operating instructions and is returned to us 
carriage paid. The warranty term is not applicable on the all consumable products.  
Proof of Purchase is required by presentation of an original invoice or receipt indicating the dealer’s 
name, the model number and date of purchase, or a Guarantee Card if appropriate. This warranty 
may  not  apply  if  any  model  or  production  number  has  been  altered,  deleted  or  removed, 
unauthorised  persons  or  organisations  have  executed  repairs,  modifications  or  alterations,  or 
damage is caused by accident, misuse or neglect.  
We regret we are unable to accept any liability for any consequential loss.  
Please note that the product is not defective under the terms of this warranty where the product, 
or any of its component parts, was not originally designed and / or manufactured for the market in 
which it is used. 
These statements do not affect your statutory rights as a customer. 
 
If  your  AB  Aqua  Medic  GmbH  product  does  not  appear  to  be  working  correctly  or  appears  to  be 
defective please contact your dealer in the first instance. 
Before calling your dealer please ensure you have read and understood the operating instructions. 
If you have any questions your dealer cannot answer please contact us. 
 
Our policy is one of continual technical improvement and we reserve the right to modify and adjust 
the specification of our products without prior notification. 
 

AB AQUA MEDIC GmbH - Gewerbepark 24 -49143 Bissendorf/Germany 

- Technical changes reserved – 10/2009

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for Premium 90/150

Page 1: ... in der Lage die anorganischen Inhaltsstoffe und andere Schadstoffe Ihres Leitungswassers ohne Zudosierung von Chemikalien um 95 98 Nitrat und Silikat ca 70 zu vermindern Lesen Sie die Bedienungsanleitung sorgfältig Dies vermeidet Fehlbedienungen und Reklamationen GmbH Gewerbepark 24 49143 Bissendorf Germany __________________________________________________________________________________________...

Page 2: ...tungswasserzulauf in den Vorfilter 1 2 Konzentratablauf Abwasser am Spülventil 3 3 Reinwasser Permeat 2 4 Wasserhahnanschluss Den Wasserhahnanschluss an einen 3 4 Wasserhahn Kaltwasser anschließen ggfs Adapterstück zwischenschalten nicht im Lieferumfang enthalten 3 Inbetriebnahme Wenn alle Anschlüsse fest sitzen kann das Wasser aufgedreht werden Der minimale Wasserdruck für den Betrieb der Anlage ...

Page 3: ...lventil 4 Schraubkappe Umkehrosmosemodul 5 Umkehrosmosemodul mit Membrane 6 Vorfiltergehäuse für Feinfilter 7 Vorfiltergehäuse für AK Filter 8 O Ringe 9 Flachdichtung 10 Feinfiltereinsatz 11 Aktivkohlefiltereinsatz 12 Halteklammer Modulgehäuse 13 Befestigungswinkel ...

Page 4: ... Ggfs Vorfilter wechseln Es fließt zu wenig Reinwasser Prüfen ob auch zu wenig Abwasser fließt und ggfs Vorfilter wechseln s o Wasserdruck zu niedrig Hier können Sie als normaler Wasserverbraucher wenig machen wenn der niedrige Wasserdruck schon vom Wasserwerk geliefert wird nachfragen Für die Anlage sollte der Wasserdruck mind 3 bar betragen Modul verstopft oder verbraucht Die Membrane muss erneu...

Page 5: ...ienachweis gilt der Original Kaufbeleg Während dieser Zeit werden wir das Produkt kostenlos durch Einbau neuer oder erneuerter Teile instand setzen ausgenommen Frachtkosten Im Fall dass während oder nach Ablauf der Garantiezeit Probleme mit Ihrem Gerät auftreten wenden Sie sich bitte an Ihren Fachhändler Diese Garantie gilt nur für den Erstkäufer Sie deckt nur Material und Verarbeitungsfehler die ...

Page 6: ...and silicate approx 70 without adding any chemicals In the aquarium you prevent overfertilization of the water from the tap The growth rate of diatoms and other microalgaes is reduced Residues of pesticides and other toxic substances do not get into the aquarium Please read the manual carefully This prevents failures and complaints GmbH Gewerbepark 24 49143 Bissendorf Germany _____________________...

Page 7: ...et into the sediment pre filter 1 2 Concentrate outlet waste water at flushing valve 3 3 Pure water permeat 2 4 Tap water connection Fix the water connection piece to a 3 4 water tap cold water If it does not fit use a reduction piece not included in shipment 3 Starting When all connections are tight you can open the water tap The minimum water pressure for the unit is 3 bar The nominal capacity i...

Page 8: ...p of module housing 5 Reverse osmosis module incl membrane 6 Pre filter housing for fine filter 7 Pre filter housing for activated carbon filter 8 O rings 9 Flat gasket 10 Fine filter element 11 Activated carbon filter element 12 Holding clip for module s housing 13 Mounting bracket ...

Page 9: ...and check the membrane power Waste water flow rate is too low Check if the pre filter is blocked The water pressure at the pressure gauge behind the pre filters must not be much lower at the most 0 5 bar than the water supply pressure Maybe change the pre filter Pure water flow rate is too low Check the waste water flow rate If it is to low too change the pre filter Tap water pressure is too low I...

Page 10: ...ble products Proof of Purchase is required by presentation of an original invoice or receipt indicating the dealer s name the model number and date of purchase or a Guarantee Card if appropriate This warranty may not apply if any model or production number has been altered deleted or removed unauthorised persons or organisations have executed repairs modifications or alterations or damage is cause...

Page 11: ...rofessionnels Cet appareil vous permet de retirer en moyenne de l ordre de 95 à 98 les substances inorganiques et autres impuretés nitrates et silicates 70 présentes dans votre eau de conduite sans avoir recours à des produits chimiques Veuillez lire soigneusement les instructions Ceci empêche les erreurs de manipulation et les réclamations GmbH Gewerbepark 24 49143 Bissendorf Germany ____________...

Page 12: ... concentrat au niveau de la soupape de rinçage 3 3 Perméat eau osmosée 2 4 Raccordement robinet eau de conduite Connecter le raccordement du robinet d eau de conduite avec un robinet type 3 4 ou intercaler un réducteur non compris dans l emballage 3 Mise en route Lorsque tous les raccordements sont effectués il est possible d ouvrir l arrivée d eau La pression minimale pour le fonctionnement de l ...

Page 13: ...çage 4 Couvercle à vis module d osmose 5 Module d osmose avec membrane 6 Boîtier du préfiltre pour filtre fin 7 Boîtier préfiltre pour filtre charbon actif 8 Joint 9 Joint plat 10 Filtre 11 Filtre à charbon actif 12 Pince de fixation boîtier du module 13 Equerre de fixation ...

Page 14: ...eté élevée l appareil peut très rapidement se calcifier et il faut alors le retourner à l usine Il n y a pas assez de concentrat Vérifier si le préfiltre est colmaté La pression du manomètre situé derrière le préfiltre ne doit pas être inférieure 0 5 bar à celle de la pression de l eau de conduite voir système de coupure Le cas échéant changer le préfiltre Il n y a pas assez de perméat Vérifier si...

Page 15: ...eil doit être stocké à l abri du gel Le gel détruit la membrane 7 Garantie AB Aqua Medic GmbH assure une garantie de 12 mois à partir de la date de l achat sur tous les défauts de matériaux et d assemblage de l appareil Elle ne couvre pas les pièces d usure comme le tube UV C ou la gaine de quartz Le ticket de caisse original sert de preuve d achat Durant cette période l appareil est remis gratuit...

Reviews: