Aqua Lung SEA LV2 Technical Manual Download Page 4

SEA MK / LV2 Technical Manual

4   

Introduction

This manual provides factory prescribed procedures for 

the correct service and repair of this Aqua Lung product. 

It is not intended to be used as an instructional manual for 

untrained personnel. The procedures outlined in this manual 

are to be performed only by personnel who have received 

Factory Authorized training through an Aqua Lung Service 

& Repair Seminar. If you do not completely understand all of 

the procedures outlined in this manual, contact Aqua Lung 

to speak directly with a Technical Advisor before proceeding 

any further. 

Scheduled Service

This product should be given the same care and maintenance 

as life support equipment.  It is therefore important to perform 

scheduled overhaul service for the complete unit, according 

to the procedures outlined in this manual on a regularly 

scheduled basis; 

once every two years

 with normal use.

General Guidelines

1.

 In order to correctly perform the procedures outlined in 

this manual, it is important to follow each step exactly in the 

order given.  Read over the entire manual to become familiar 

with all procedures before attempting to disassemble the 

product in this manual and to learn which specialty tools and 

replacement parts will be required.  Keep the manual open 

beside you for reference while performing each procedure. 

Do not rely on memory.

2.

 All service and repair should be carried out in a work area 

specifically set up and equipped for the task. Adequate lighting, 

cleanliness and easy access to all required tools are essential 

for an efficient repair facility.

3.

 As each unit is disassembled, reusable components should 

be segregated and not allowed to intermix with non-reusable 

parts or parts from other units.  Delicate parts, including inlet 

fittings and crowns which contain critical seating surfaces, 

must be protected and isolated from other parts to prevent 

damage during the cleaning procedure.

4.

 Use only genuine Aqua Lung ® parts provided in the over-

haul parts kit for this product. DO NOT attempt to substitute 

an Aqua Lung ® part with another manufacturer’s, regardless 

of any similarity in shape or size.

5.

 Do not attempt to reuse mandatory replacement parts 

under any circumstances, regardless of the amount of 

use the product has received since it was manufactured 

or last serviced.

6.

 When reassembling, it is important to follow every torque 

specification prescribed in this manual, using a calibrated torque 

wrench. Most parts are made of aluminum, marine brass or 

plastic and can be permanently damaged by excessive stress.

Pinch Method

Press upwards on sides of o-ring to 

create a protrusion. Grab o-ring or  

insert o-ring tool at protrusion. 

General Conventions

Unless otherwise instructed, the following terminology and 

techniques are assumed:

1.

 When instructed to 

remove

unscrew

 or 

loosen

 a threaded 

part, turn the part counter-clockwise.
When instructed to 

install

screw

 or 

tighten

 a threaded 

part, turn the part clockwise.

2.

 When instructed to 

"OPEN"

 the handwheel, turn the 

handwheel counter-clockwise. The 

red indicator ring will 

not be visible

 in the handwheel window, this indicates the 

unit is in the 

"ON"

 position.

When instructed to 

"CLOSE"

 the handwheel, turn the 

handwheel clockwise. The 

red indicator ring will be 

visible

 in the handwheel window, this indicates the unit 

is in the 

"OFF"

 position.

3.

 The method used to depressurize your system will depend 

on its configuration:

•  SEA w/ handwheel: Depress second stage purge button for 

5 seconds and release for 5 seconds. Repeat this procedure 

until the system is depressurize.

•  SEA w/o handwheel: Breathe the unit down by taking 5 

breaths from the second stage and pause for 5 seconds. 

Repeat this procedure until the system is depressurized.

4.

 When instructed to fill or refill the cylinder, 3000 PSI (207 

BAR) will be the standard fill pressure used for testing purposes 

in this manual. Upon completion of all testing, fill the cylinder to 

its full capacity as marked. (

Reference the Filling Procedures 

section of the User's Manual). 

 

5.

 The following acronyms are used throughout the manual: 

LP

 is Low Pressure; 

MP

 is Medium Pressure; and 

HP

 is 

High Pressure.

6.

 Numbers in parentheses reference the key numbers on the 

exploded parts schematics. 

For example

, in the statement, 

“... remove the o-ring (7) from the crown (8) “...the number 7 

is the key number to the crown o-ring.

7.

 When instructed to remove an o-ring, use the pinch 

method (see illustration below) or use a brass or plastic 

o-ring removal tool. Avoid using hardened steel picks 

(unless directed), as they may damage the o-ring sealing 

surface. All o-rings that are removed are discarded and 

replaced with brand new o-rings.

Summary of Contents for SEA LV2

Page 1: ...Tertiary Branding TECHNICAL MANUAL Survival Egress Air SEA MK LV2 Rev 6 17...

Page 2: ...ANUAL PN 108348 You can contact a Technical Adviser via e mail at sreilly aqualung com jbutner aqualung com grubin aqualung com Warnings Cautions Notes Pay special attention to information provided in...

Page 3: ...bly 16 Second Stage LV2 Reassembly 17 Final Testing 19 Table 1 Troubleshooting Guide First Stage 20 Table 2 Troubleshooting Guide Second Stage 21 Table 3 List of Tools and Service Kits 22 Table 4 Torq...

Page 4: ...dless of the amount of use the product has received since it was manufactured or last serviced 6 When reassembling it is important to follow every torque specification prescribed in this manual using...

Page 5: ...to the exploded parts drawing which references all mandatory replacement parts These parts should be replaced with new service kit parts Old parts should not be reused under any circumstances regardle...

Page 6: ...ing surface CAUTION Be careful not to damage the fill port 33 with the wrench while removing the pressure gauge 36 8 Using the 3 4 socket and flex wrench unscrew the bonnet 21 from the first stage bod...

Page 7: ...o holes on top of the retainer cap 2 Unscrew the retainer cap from the first stage body 8 20 Using your fingers peel the retainer cover 1 off the retainer cap 2 18 Using a 9 16 socket and flex wrench...

Page 8: ...it aside for reuse Second Stage MK Disassembly 1 Use diagonal pliers to cut the strap clamp 50 and remove the mouthpiece 49 from the box bottom 54 Inspect the mouthpiece to ensure it is free of any t...

Page 9: ...w the hard cover 64 from the box bottom 69 Use the retaining ring wrench to unscrew the retaining ring 65 from the box bottom 3 Lift out the front cover 66 and diaphragm 48 Inspect the diaphragm for a...

Page 10: ...ean supple and free of any blemishes WARNING Use only genuine Aqua Lung parts sub assemblies and components when ever assembling any Aqua Lung product DO NOT attempt to substitute an Aqua Lung part wi...

Page 11: ...l port CAUTION To avoid damaging the fill port 33 do not over torque 5 Insert the shaft of the piston 4 into the spring 7 Press down on the retainer cap 2 and tighten the cap onto the first stage body...

Page 12: ...the first stage body 8 Use the valve handle retainer tool to tighten the pin pressure indicator until hand tight 14 Thread the safety plug 9 into the lower HP port opposite the fill port on the first...

Page 13: ...t sits on top of the bonnet 21 Face the round edge on the indicator ring 20 outward and thread the indicator ring onto the bonnet until it bottoms out 21 When the indicator ring 20 bottoms out turn it...

Page 14: ...4 BAR with an inlet pressure of 3000 PSI 207 BAR 5 Close the handwheel 18 and open the bleed valve to depressurize the system Remove the test gauge from the MP hose 11 6 Since there is nothing attach...

Page 15: ...n on the valve body to compress the spring 57 while threading it onto the inlet fitting Continue tightening the valve body onto the inlet fitting until it stops CAUTION If resistance is felt immediate...

Page 16: ...valve body to prevent it from rotating inside the box bottom 54 Use a 3 4 socket and inch pound torque wrench to apply 50 in lbs 5 6 Nm of torque to the inlet fitting NOTE Set the valve body assembly...

Page 17: ...he stem through the center hole of the exhaust port Pull the stem through until the barb is on the opposite side of the hole in the exhaust port Examine the flap of the exhaust valve to make sure it i...

Page 18: ...e retaining ring wrench to screw the retaining ring 65 into the box bottom 69 hand tight Place the hard cover 64 over the front cover 66 and screw down until hand tight 7 Install mouthpiece 70 onto th...

Page 19: ...manual DO NOT issue to a crew member or passenger any SEA which exhibits any signs of leakage or unsatisfactory performance until the problem has been thoroughly diagnosed and repairs have been made a...

Page 20: ...spring 7 is weakened or damaged 3 Replace spring 7 4 The HP seat 6 is worn or damaged 4 Replace HP seat 6 5 The HP crown seating surface in first stage body 8 is worn or damaged 5 Replace first stage...

Page 21: ...d 1 Re torque MP hose 11 at second stage fitting or replace hose 2 The MP hose o ring 25 is damaged 2 Replace the o ring 25 Water entering second stage 1 The mouthpiece 49 or 70 is incorrectly fitted...

Page 22: ...A MK Carrying tools 111610 MP Test Gauge 0 400 psi Checking medium pressure 108357 Repair Mat Service and maintenance 108362 Soft Cases MP Test Gauge Cover for MP Test Gauge 108325 SCUBA Fill Adapter...

Page 23: ...oot 7 8 Crowfoot Removal Installation of First Stage Body 8 Removal Installation of MP Hose 11 Removal Installation of Pressure Gauge 36 9 43226 103006 9 43001 3 4 Socket 9 16 Socket 3 8 Socket Remova...

Page 24: ...ncluded in Tool Kit N A Torque Wrench in lbs Apply torque to parts listed in Table 4 Torque Specifications Not included in Tool Kit N A Torque Wrench ft lbs Apply torque to parts listed in Table 4 Tor...

Page 25: ...urge Flow MP 135 20 PSI 9 3 1 4 BAR 5 SCFM 142 LPM flow rate minimum TABLE 6 RECOMMENDED CLEANERS AND LUBRICANTS LUBRICANT CLEANER APPLICATION SOURCE Christo Lube MCG 111 All o rings Aqua Lung PN 8204...

Page 26: ...se only a soft nylon toothbrush to scrub away any deposits Rinse in fresh water and thoroughly blow dry using low pressure filtered air Cleaning Hoses 1 Hose fittings Ultrasonically clean with soapy w...

Page 27: ...0304P O ring 10 pk 39 845034 Washer 40 100688 Spring Pressure Gauge 41 100613 Plunger 42 100607 Retainer 43 079105 Cylinder 1 5 ft 3000 PSI Black Aluminum 079120 Cylinder 2 0 ft 3000 PSI Black Aluminu...

Page 28: ...31 Mouthpiece Black 50 104913 Clamp Strap Black 23 820015P O ring 10 pk 51 108438 Inlet Fitting Black 25 820010P O ring 25 pk 52 100907 Cover Exhaust Valve 53 100922 Exhaust Valve 54 100905 Box Bottom...

Page 29: ...t Bearing 59 100945 Valve Body 60 100923 Lever 61 104129 Washer 62 102510 Locknut 67 108371 Cap Exhaust Valve 108371Y Cap Exhaust Valve Yellow 68 100122 Exhaust Valve 69 108374 Box Bottom LV2 Black 23...

Page 30: ...SEA MK LV2 Technical Manual 30 MAINTENANCE NOTES...

Page 31: ...31 MAINTENANCE NOTES...

Page 32: ...hone 760 597 5000 Fax 760 597 4900 www aqualung com militaryandprofessional Blue Pantone 2728C Primary Preferred Branding Secondary Branding Tertiary Branding 2017 Aqua Lung International Survival Egr...

Reviews: