
Doc. 12-7834-r04 (2/16/16)
44
DIVE OPERATION
© Aqua Lung International, Inc. (2015)
GAS/TRANSMITTER SWITCHES
!
WARNINGS:
• Historically, many accidents and near misses have occurred by switching to the wrong gas at the
wrong depth. DO NOT attempt gas switch decompression dives without proper education and
training to do so from an internationally recognized training agency.
• Diving deeper than 130 FT (39 M), will greatly increase your risk of decompression sickness.
• Decompression diving is inherently hazardous and greatly increases your risk of decompression
sickness, even when performed according to the dive computer's calculations.
• Using an i450T is no guarantee of avoiding decompression sickness.
• The i450T enters Violation Mode when a situation exceeds its capacity to predict an ascent
procedure. These dives represent gross excursions into decompression that are beyond the
boundaries and spirit of the i450T's design. If you are following these dive profiles, Aqua Lung
advises that you should not use an i450T.
• If you exceed certain limits, the i450T will not be able to help you get safely back to the surface.
These situations exceed tested limits and can result in loss of some functions for 24 hours after the
dive in which a violation occurred.
OVERVIEW
• All dives begin with GAS 1 and TMT 1.
• The GAS and TMT default to # 1 after 10 minutes on the surface.
• Gas switches can only be made when a Dive Main screen is displayed.
• Gases cannot be switched while on the surface.
• The Gas Switch Menu cannot be accessed during the sounding of alarms.
• If an alarm strikes while in the Gas Switch Menu, the switch operation is terminated (reverting to the Dive Main
screen.
SELECT
ADV
.
LIGHT
MODE
DIVE MAIN
to Gas Switch
screen
SELECT
ADV
.
LIGHT
MODE
to move
(
■)
up
to move
(
■)
down
to select
gas
GAS/TMT SWITCH MENU
current gas
settings
SELECT
ADV
.
LIGHT
MODE
CONFIRM SWITCH
current
PO
2
value
FO
2
setting
to confirm
switch
SEARCHING
NOTE: If no TMT is
active the Searching
screen will be bypassed.
Summary of Contents for i450T
Page 1: ...Aqua Lung International Inc 2015 Dive Computer Owner s Manual Doc 12 7834 r04 2 16 16 i450T...
Page 6: ...Doc 12 7834 r04 2 16 16 6 Aqua Lung International Inc 2015 GETTING STARTED...
Page 12: ...Doc 12 7834 r04 2 16 16 12 Aqua Lung International Inc 2015 WATCH MODE...
Page 19: ...Doc 12 7834 r04 2 16 16 19 Aqua Lung International Inc 2015 DIVE FEATURES...
Page 25: ...Doc 12 7834 r04 2 16 16 25 Aqua Lung International Inc 2015 DIVE SURFACE MODE...
Page 40: ...Doc 12 7834 r04 2 16 16 40 Aqua Lung International Inc 2015 DIVE OPERATION...
Page 52: ...Doc 12 7834 r04 2 16 16 52 Aqua Lung International Inc 2015 GAUGE MODE...
Page 56: ...Doc 12 7834 r04 2 16 16 56 Aqua Lung International Inc 2015 FREE MODE...
Page 67: ...Doc 12 7834 r04 2 16 16 67 Aqua Lung International Inc 2015 COMPASS MODE...
Page 73: ...Doc 12 7834 r04 2 16 16 73 Aqua Lung International Inc 2015 REFERENCE...
Page 79: ...Doc 12 7834 r04 2 16 16 79 Aqua Lung International Inc 2015 TECHNICAL DATA...
Page 86: ...www aqualung com...