Doc. 12-7834-r04 (2/16/16)
23
DIVE FEATURES
© Aqua Lung International, Inc. (2015)
AUDIBLE ALARM
While operating in Dive or Gauge Mode, the audible alarm will emit 1 beep per second for 10 seconds when
alarms strike, unless it is set to Off. During that time, the audible alarm can be acknowledged and silenced by
pressing the SELECT button.
An LED warning light, on the side of the housing, is synchronized with the audible alarm and flashes as the au
-
dible alarm sounds. It will turn off when the alarm is silenced. The audible and LED alarms will not be active if the
audible alarm is set to OFF (a Set Alarms setting).
Free Dive Modes have their own alarms which emit multiple beeps multiple times which cannot be acknowledged
or set to OFF.
Events that emit (10) beeps >> each sound for ½ sec with ½ sec silence between beeps:
• Watch Daily Alarm.
• Watch CDT Alarm.
• DIVE, GAUGE - GTR Alarm.
• DIVE, GAUGE - Turn Alarm (TMT 1).
• DIVE, GAUGE - Press Alarm (TMT in use).
• DIVE, GAUGE - Loss of Link (Dive Mode).
• DIVE, GAUGE - Ascent Rate too fast.
• DIVE, GAUGE - Depth Alarm.
• DIVE, GAUGE - EDT Alarm.
• DIVE - DTR Alarm.
• DIVE - N2 Alarm.
• DIVE - entry into Decompression.
• DIVE - Conditional Violation.
• DIVE - Delayed Violations 1, 2.
• DIVE, GAUGE - Delayed Violation 3.
• DIVE, GAUGE - entry into Violation Gauge Mode.
• DIVE - PO2 Warning and Alarm.
• DIVE - O2 Warning and Alarm.
• DIVE - Gas Switch Alarm.
Events that emit (3) beeps >> each sound for ½ sec with ½ sec silence between beeps:
• DIVE, GAUGE - Ascent Rate warning.
• FREE - Delayed Violation 3.
Events that emit (3) sets of (3) beeps >> each sound for ½ sec with ½ sec silence between beeps and ½ sec
silence between sets:
• FREE - SRT Alarm.
• FREE - RDI Alarm. RDI does not alarm at the DA alarm depths.
• FREE - CDT Alarm.
• FREE - N2 Alarm.
• FREE - Violation, entry into Decompression.
Events that emit (3) sets of (3) beeps >> each sound for
⅛
sec with
⅛
sec silence between beeps and ¼ sec
silence between sets:
• FREE - DA1 to DA3 Alarms.
Events that emit (2) beeps >> each sound for 1 sec with ½ sec silence between beeps:
• FREE - RTI Alarm.
Summary of Contents for i450T
Page 1: ...Aqua Lung International Inc 2015 Dive Computer Owner s Manual Doc 12 7834 r04 2 16 16 i450T...
Page 6: ...Doc 12 7834 r04 2 16 16 6 Aqua Lung International Inc 2015 GETTING STARTED...
Page 12: ...Doc 12 7834 r04 2 16 16 12 Aqua Lung International Inc 2015 WATCH MODE...
Page 19: ...Doc 12 7834 r04 2 16 16 19 Aqua Lung International Inc 2015 DIVE FEATURES...
Page 25: ...Doc 12 7834 r04 2 16 16 25 Aqua Lung International Inc 2015 DIVE SURFACE MODE...
Page 40: ...Doc 12 7834 r04 2 16 16 40 Aqua Lung International Inc 2015 DIVE OPERATION...
Page 52: ...Doc 12 7834 r04 2 16 16 52 Aqua Lung International Inc 2015 GAUGE MODE...
Page 56: ...Doc 12 7834 r04 2 16 16 56 Aqua Lung International Inc 2015 FREE MODE...
Page 67: ...Doc 12 7834 r04 2 16 16 67 Aqua Lung International Inc 2015 COMPASS MODE...
Page 73: ...Doc 12 7834 r04 2 16 16 73 Aqua Lung International Inc 2015 REFERENCE...
Page 79: ...Doc 12 7834 r04 2 16 16 79 Aqua Lung International Inc 2015 TECHNICAL DATA...
Page 86: ...www aqualung com...