Doc. 12-7834-r04 (2/16/16)
37
DIVE SURFACE MODE
© Aqua Lung International, Inc. (2015)
8. SAMPLING (SAMPLE RATE)
The Sample Rate controls how frequently the i450T stores a data snapshot for PC Download
during a dive. Setting options are 2, 15, 30, or 60 second intervals. Shorter intervals will provide a
more precise record of your dives.
NOTE: New data will automatically overwrite the oldest data in memory when the memory
becomes full. The i450T Log and PC Download data is stored separately in different parti-
tions of the memory. The Log only stores a short summary of each dive. Alternately, the PC
Download function stores much larger files for each dive. Depending on the chosen set-
tings and dive durations, it is possible to see dives stored in the i450T's onboard Log that
have already been overwritten in the PC Download Partition.
Choosing a longer Sample
Rate interval will consume less memory per dive.
Remember to download your dives more
frequently if you are using a shorter Sample Rate interval.
SELECT
ADV
.
LIGHT
MODE
to save
setting
SET SAMPLING RATE
flashing
to increase
value
to decrease
value
9. TMT
MENU (TRANSMITTER MENU)
The i450T can use up to 3 transmitters to monitor gas supplies. The TMT Menu allows for the pro-
gramming of the wrist unit to receive the signals from selected Aqua Lung transmitters. See the
Dive Mode Features section (p. 24) for further information on transmitters.
NOTE: If the TMT is set OFF for the active gas, the letters SPG will be displayed in place of
a pressure reading on the Main Screen.
NOTE: Transmitter 2 cannot be set to ON unless transmitter 1 is set to ON. Likewise, tran-
mitter 3 cannot be set to ON unless transmitter 2 is also set ON. If you attempt to do so, the
i450T will display the message TMT 1(2) MUST BE SET ON FIRST.
SELECT
ADV
.
LIGHT
MODE
to move
(
■)
up
to move
(
■)
down
to select
option
TMT SET MENU
SELECT
ADV
.
LIGHT
MODE
to move
(
■)
up
to move
(
■)
down
to select
option
OFF or ON
returns to
Set TMTMenu
SET TMT 1 (2, 3)
current 6 digit
frequency setting
Summary of Contents for i450T
Page 1: ...Aqua Lung International Inc 2015 Dive Computer Owner s Manual Doc 12 7834 r04 2 16 16 i450T...
Page 6: ...Doc 12 7834 r04 2 16 16 6 Aqua Lung International Inc 2015 GETTING STARTED...
Page 12: ...Doc 12 7834 r04 2 16 16 12 Aqua Lung International Inc 2015 WATCH MODE...
Page 19: ...Doc 12 7834 r04 2 16 16 19 Aqua Lung International Inc 2015 DIVE FEATURES...
Page 25: ...Doc 12 7834 r04 2 16 16 25 Aqua Lung International Inc 2015 DIVE SURFACE MODE...
Page 40: ...Doc 12 7834 r04 2 16 16 40 Aqua Lung International Inc 2015 DIVE OPERATION...
Page 52: ...Doc 12 7834 r04 2 16 16 52 Aqua Lung International Inc 2015 GAUGE MODE...
Page 56: ...Doc 12 7834 r04 2 16 16 56 Aqua Lung International Inc 2015 FREE MODE...
Page 67: ...Doc 12 7834 r04 2 16 16 67 Aqua Lung International Inc 2015 COMPASS MODE...
Page 73: ...Doc 12 7834 r04 2 16 16 73 Aqua Lung International Inc 2015 REFERENCE...
Page 79: ...Doc 12 7834 r04 2 16 16 79 Aqua Lung International Inc 2015 TECHNICAL DATA...
Page 86: ...www aqualung com...