REASSEMBLY PROCEDURES
NOTE: Before starting reassembly, it is important to inspect all parts, both new and those that are
being reused, to ensure that every part and component is perfectly clean and free of any dust,
corrosion, or blemishes. Check all o-rings to ensure they are clean and supple before dressing with
either Christo-Lube
®
or Dow 111 silicone grease.
WARNING: Use only genuine Aqua Lung parts, subassemblies, and components whenever assem-
bling any Aqua Lung product. DO NOT attempt to substitute an Aqua Lung part with another
manufacturer’s, regardless of any similarity in shape, size, or appearance. Doing so may render the
product unsafe, and could result in serious injury or death.
1.
Install the o-ring (28) onto the vane adjustment switch (27).
2.
Mate the stem of the vane switch into its respective hole in the box bottom (29), above the outlet boss,
and align the mating pin above the positioning guide (see Fig. 9). When the switch is correctly aligned,
press it down and into place so that it is properly seated inside the box bottom.
Fig. 10 – Loading Circlip Tool
Flat side faces down
Fig. 9 – V.A.S. Alignment
3.
Press the circlip (26) into the recessed ledge in the forks of the Circlip/ Retaining Ring Tool
(P/N 107846), with its flat side facing down and the open end facing out of the tool (see Fig. 10). The
spring tension of the tool will hold the circlip in place while it is being positioned inside the box
bottom.