18. Using your fingers, thread the sheath onto the connecting nut until fingertight. While holding the
sheath with a 8mm wrench, tighten the connecting nut with another 8mm wrench (see Fig. 21).
Fig. 21 – Tightening Connecting Nut to
Sheath
19. While keeping the valve body pressed against the sidewall, thread the inlet fitting (31) into the valve
body (see Fig. 22). Attach a 19mm (
³⁄₄
") crows-foot adapter to a torque wrench and tighten the inlet
fitting to 85±3 inch-pounds.
Press against valve body
20. Install two new o-rings (34 & 36) onto the IP hose.
Fig. 22 – Install Inlet Fitting