![Aqua Lung GLACIA Service & Repair Manual Download Page 21](http://html1.mh-extra.com/html/aqua-lung/glacia/glacia_service-and-repair-manual_2958510021.webp)
Glacia Second Stage Service & Repair Manual
19
© 2000 Aqua Lung America, Inc.
Table 4
Torque Specifications
PART NUMBER
DESCRIPTION / KEY NUMBER
TORQUE
090015
102035
LP Hose Female Fitting / 35
40 (±2) inch-lbs
090027
109511
Inlet Fitting / 31
85 (±3) inch-lbs
109508
Insert / 18
85 (±3) inch-lbs
109509
Ribbed Plug / 16
20 (±2)inch-lbs
Table 5
Test Bench Specifications
TEST
CONDITION
ACCEPTABLE RANGE
Leak test
Inlet 2,500-3,000 (±100) psi
None
Intermediate pressure
Inlet 2,500-3,000 (±100) psi
130-135 psi
Intermediate pressure creep Inlet 2,500-3,000 (±100) psi
5 psi max between 5 to 15 seconds
after cycling regulator (purge)
Opening effort
Inlet 2,500-3,000 (±100) psi,
+1.0 to +1.6 inch H
2
0 (primary)
intermediate pressure 130-135 psi
Flow effort
Intermediate pressure 130-135 psi
+6 inches H
2
0 (maximum)
at 15 SCFM
Purge flow
Intermediate pressure 130-135 psi
5.0 SCFM flow rate (minimum)
Summary of Contents for GLACIA