FREE FLOW / WATER DUMP VALVE (continued)
Step 10: Thread in the valve seat
(55) with valve stem (57).
Step 11: Place two copper washers
(56) on top of the valve seat (55) in
the valve body (52).
Step 12: Place o-ring (59) into
the valve bonnet (60).
Step 13: Place Teflon washer
(58) over the o-ring (59) in the
valve bonnet (60).
Step 14: Place the valve stem
(57) into the valve body (52)
over the seat (55).
Step 15: Place the valve bonnet
assembly over the valve stem
(57) into the valve body (52).
Step 16: Thread the valve bonnet
(60) into the valve body (52).
Step 17: Tighten the valve
bonnet (60) with a 11/16"
socket to 35 ft.lbs (47 Nm).
Step 18: Free flow / water dump
valve assembled.
NOTE:
Final assembly instructions for the Free Flow / Water Dump Valve are detailed in the
Helmet Final Assembly section of the Operations and Maintenance Manual.