— Page 13 —
© 2008 Aqua-Hot
®
600-D Hydronic Heating System Installation Manual
section 2: Hydronic Heating system
Wiring the Heat Exchangers:
1.
Run two 18-gauge wires, red for (+) and black for (-),
from each particular heating zone’s heat exchanger to
the electronic controller. Reference Figure 21.
2.
Label the wires indicating the heating zone they pertain
to (e.g., Living Room, Bathroom, Bedroom, etc.).
3.
Insert all heat exchanger wires into the appropriate ter-
minal/heating zone location on the electronic control-
ler. Reference Figure 21 and Appendix A.
4.
Wire all heat exchangers in the same zone in-series.
5.
Connect all electronic controller wires to the positive
and negative leads of the heat exchanger. Reference
Figure 21.
NOTE:
Tolerance
+/- .030
+ (Positive) Red Wires
To Aqua-Hot’s Terminal
Block
- (Ground) Black Wires
To a chassis ground source
Mounting Tab
3.63 in.
13.06 in.
6.44 in.
14.44 in.
Figure 21
Figure 20
Reset Button
(Secondary
Power Source)
12 Volt-DC Screw
Terminal
(Primary
Power Source)
12 Volt-DC Screw
Terminal
Ground Wire
Screw Terminal
Terminal
Strip/Plug
Pin Jumper
Electronic Controller Board
To Motorhome
From Hydronic Heating
System Wiring Harness
Wire
Loom
Wire
Loom
Summary of Contents for 600-D
Page 1: ...2008 Aqua Hot Heating Systems Inc Installation Manual...
Page 43: ...Appendix B Appendix B Wire Gauge Information...
Page 45: ...Appendix C Appendix C Electronic Controller Features...
Page 48: ...Appendix D Appendix D Antifreeze Types...
Page 50: ...Appendix E Appendix E Antifreeze Mixture Water Quality Recommendations...
Page 52: ...Appendix F Appendix F Antifreeze Terms and Mixture Ratio...