6.1 Manual reset of error conditions
In block (fault) status, the user can cancel the current error and force a new attempt by pressing and releasing the
“
Reset
” key.
If the action is successful, the red warning LED ( ) goes out and the system returns to normal operation.
Instead, if the error condition remains, you must take steps to eliminate the cause of the fault.
6.2 Automatic reset of error conditions
For some types of fault, automat reset attempts are contemplated.
In particular for:
-
e27
Dry operation
-
e28
Pump not primed
a new attempt is made after a few minutes, and repeated cyclically.
If an attempt is successful during the reset sequence, the sequence is interrupted, the red warning LED ( ) goes out
and the system returns to normal operation. In the case of the “Excess temperature” faults, the system resume operation
as soon as the temperature returns within the normal operating range.
6.3 Viewing the block history
The list of the faults and blocks that have occurred most recently can be consulted under the menu item “
Fault History
”.
See paragraph 5.11.
7 FACTORY SETTINGS
The system leaves the factory with a series of preset parameters, which may be changed according to the requirements
of the plant and of the user. Each change of the settings is automatically saved in the memory. The factory (or default)
settings are summed up in the following table. You can make a note of the values modified for your own installation in
the “
MEMO
” column.
As indicated in the table, some default values may differ depending on the market for which the system is
intended.
If desired, it is possible to restore the default settings, proceeding as described in paragraph 6.1.
Factory settings
Menus
Function
Parameter
Value
(*)
Value
(*)
1.5 CV
3 CV
1
Origin speed
Digital IN
1-2
Language
English
1-3
Time format
24h
AM PM
1-4
Unit of Measure
Head Unit
m (metres)
ft (feet)
Flow Unit
m3/h
US GPM
Temperature Unit
°C
°F
1-5
Pump Limits
H max (head)
MAX
Q max (flow)
MAX
1-6
SVRS
Restarting
AUTO
Disabling time
15 min
1-7
Screen
Sleep Time
1:00 h
Back lighting
100%
1-8
Password
value
0 (not active)
2-1
Manual speed type of setpoint
FLOW
FLOW
2-1
SET1
setpoint Q
5 m3/h
20 GPM 13 m
3
/h
60 GPM
setpoint %
50%
duration
8 h (10 min - 18 h /)
2-1
SET2
setpoint Q
12 m3/h
50 GPM 18 m
3
/h
80 GPM
setpoint %
70%