1 4 |
P a g e
GEN4 Controllers
LB4
Series
LBH4
Series
Simplistic in operation, these systems feature a tri-colour
LED that indicating system status and a 4-digit display to in-
dicate lamp life remaining. Pressing the button will change
the display to indicate total running time. When the UV lamp
is on and within its operating age, the LED will be green.
When the UV lamp is not on or the lamp life has expired,
the LED will be illuminated red and an audible buzzer will be
sounding. To remedy this condition, the UV lamp must be
replaced with a new genuine AQUA FLO UV lamp.
GEN5 & GEN6 Controllers
GEN5 / GEN6
Series
GENH5 /
GENH6 Series
A full colour LCD screen provides the user with a detailed
description of the system’s performance in addition to pro-
viding any applicable fault messages and system diagnos-
tics. The controllers used in both the GEN5 and GEN6
are
identical. The difference is that the GEN6 series of products
includes a UV intensity monitor. All GEN5 and GEN6 control-
lers include an “infinite expandability port” located on the
right side of the controller. Simply plug in an optional UV
sensor module into the expandability port of a GEN5 con-
troller and the system will now monitor the UV intensity of
the system!
GEN5 & GEN6
Power-up Sequence
On start up, the controller will run through a diagnostic start-up and the sequence will be dis-
played as follows on the colour LCD:
Next, the controller checks for and initializes any optional modules that may be attached to the
system.
Optional Modules Check
- UV Sensor
- Solenoid
- 4-20 mA
- WIFI
- Remote Alarm
- Flow Meter
OR