INSTALLATION & OPERATING INSTRUCTIONS
WARNING
−
RISK
OF
ELECTRIC
SHOCK
.
C
ONNECT ONLY TO A CIRCUIT
PROTECTED BY A GROUND
-
FAULT CIRCUIT
-
INTERRUPTER
.
T
HE UNIT SHOULD BE INSTALLED BY
A QUALIFIED SERVICE REPRESENTATIVE
.
A
LL ELECTRICAL WIRING OF THE MOTOR
INSTALLATION MUST BE DONE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES
.
G
ROUNDING IS REQUIRED
.
B
EFORE WORKING ON ANY
MOTOR
,
BE CERTAIN THAT THE SOURCE OF ELECTRICAL POWER IS OFF AT THE MAIN JUNCTION
BOX
.
BONDING
WIRE
−
UPON INSTALLATION OF THE PUMP
,
THE MOTOR MUST BE BONDED
WITH
(
NO SMALLER THAN
)
A
N
O
.8
AWG
(8.4
MM
2
)
SOLID COPPER CONDUCTOR PER
N
ATIONAL
E
LECTRIC
C
ODE
.
T
HE CONNECTION SHOULD BE FROM THE ACCESSIBLE WIRE
CONNECTOR ON THE MOTOR TO ALL METAL PARTS OF THE SWIMMING POOL
,
SPA
,
OR HOT
TUB STRUCTURE AND TO ALL ELECTRICAL EQUIPMENT
,
METAL CONDUIT AND METAL
PIPING WITHIN
5
FEET
(1.5
M
)
OF THE INSIDE WALLS OF THE SWIMMING POOL
,
SPA
,
OR HOT
TUB
,
WHEN THE MOTOR IS INSTALLED WITHIN
5
FEET OF THE INSIDE WALLS OF THE
SWIMMING POOL
,
SPA
,
OR HOT TUB
.
N
OTE
:
F
OR ELECTRICAL CONNECTIONS
,
SEE WIRING DIAGRAM ON MOTOR RATING PLATE
.
GENERAL
Your AQUA-FLO pump has been quality built and engineered to give maximum
efficiency under normal water pumping conditions. Consult the manufacturer for
any other applications.
LOCATION OF PUMP
For best pump performance, locate the system as close to the water source as
possible. Provide adequate access around the pump for inspection and
maintenance.
MODELS LESS TRAP
This pump was designed for below water level (flooded suction) applications.
Make sure the pump is installed at a level that will allow the pump casing (volute)
to be completely filled with water.
Two quick disconnect compression fittings are included with your pump for ease
of installation and maintenance. Make sure the fittings are correctly aligned with
pump connections to allow the o-ring to make the proper seal.
Hand tighten
only. Do not use a wrench to tighten fittings.
MODELS WITH TRAP
Avoid excessive tightening of pipe or fittings in any areas where threaded
connections are used.
For NPT threaded connections, use Quick-Seal Teflon Thread Sealing
Compound, Plasto-Joint Stick or any other sealants formulated specifically for
plastics.
2
Summary of Contents for Flo-Master CP Series
Page 1: ......