background image

VISION

7.

7.

7.

7. Data quick view and data log (aquasuite)

Data quick view and data log (aquasuite)

Data quick view and data log (aquasuite)

Data quick view and data log (aquasuite)

All data currently monitored by the aquasuite can be accessed in the “Data quick
view” section. This includes data from connected USB devices as well as hardware
data supplied by the Aqua Computer background service. Displayed data may be
filtered using the text box next to the magnifier icon, a chart shows the develop-
ment over a maximum of ten minutes. All data shown here is  not stored perma-
nently.
In contrast, the “Data log” may be used to selectively and permanently store data
from all connected Aqua Computer devices and hardware data supplied by the
background service. Logged data can then be analyzed by creating charts or be
exported to files. Data is only logged while the aquasuite software is being execut-
ed.

7.1.

7.1.

7.1.

7.1. Log settings

Log settings

Log settings

Log settings

The log settings can be accessed by clicking the “Log settings” element
below the “Data log” headline in the listing. To log data, create a new
log data set by clicking the plus symbol in the upper right corner of the

settings window. Enter name, time interval and configure automatic deletion of old
data to meet your  requirements. You may then add the data sources to log by
clicking the plus symbol in the “Data sources” window section. You may add an
unlimited number of data sources to each log data set, the total number of log
data sets is also unlimited.

7.2.

7.2.

7.2.

7.2. Analyze data

Analyze data

Analyze data

Analyze data

Logged data can be visually evaluated as charts. To do so, select “Ana-
lyze data” below the “Data log” headline in the listing. The chart will ini-
tially be empty, directly below the chart are eight buttons to modify the

chart. In the lower section of the window, the chart data can be configured.
To add data to the chart, first select the “Data sources” tab in the chart configura-
tion and select a data set to be displayed. If no data sources are available, you
will have to configure the log settings as described in the chapter “Log settings” of
this manual. Select the time period to be displayed on the right side of the window
and add the data to the chart by clicking the “Add data to chart” button. Repeat
this procedure if you want to display more than one data set in the chart. 
You may modify the chart using the “Chart setup” and “Data series setup” tabs.
Finally, you can use the “Chart manager” tab to save the current chart configura-
tion and to load or delete previously saved configurations. All saved chart configu-
rations will be available on overview pages for the “Log data chart” element. 
The currently displayed chart can be edited by using the buttons directly below the
chart and may also be saved as an image file. The button corresponding to the
currently selected function is highlighted by an orange frame. Please refer to the
following list for details on each function:

© 2020

Aqua Computer GmbH & Co. KG

- 9 -

Gelliehäuser Str. 1, 37130 Gleichen

computer

aqua

Summary of Contents for VISION RGBpx

Page 1: ...and installation manual VISION RGBpx aquasuite version X 24 Current as of July 2020 All information contained in this manual is subject to change without prior notice All rights reserved 2020 Aqua Com...

Page 2: ...chart 7 6 8 User defined Images text drawing elements 8 6 9 Export and import of overview pages 8 7 Data quick view and data log aquasuite 9 7 1 Log settings 9 7 2 Analyze data 9 7 3 Manual data expor...

Page 3: ...eorder menu items 19 16 3 Units 20 16 4 Application start up 20 16 5 Service administration 20 16 6 Audio and video 20 16 7 Updates and update service 20 17 Technical details and care instructions 21...

Page 4: ...RGBpx 21822 cuplex kryos sTRX4 with VISION RGBpx 21822 cuplex kryos sTRX4 with VISION RGBpx 21822 The cuplex kryos NEXT ships with a separate installation manual Install the water block according to t...

Page 5: ...llation For installation and update service vali dation an internet connection is required The latest aquasuite version may also be installed if no suitable update service pe riod has been found in a...

Page 6: ...desktop mode for an overview page by clicking the monitor symbol in the list of overview pages Desktop mode can only be enabled for one overview page at a time With desktop mode enabled elements of t...

Page 7: ...unit can be con figured for individual values 6 6 6 6 6 6 6 6 Detailed data elements Detailed data elements Detailed data elements Detailed data elements If the currently selected overview page is un...

Page 8: ...will require some programming experience for configuration 6 9 6 9 6 9 6 9 Export and import of overview pages Export and import of overview pages Export and import of overview pages Export and import...

Page 9: ...umber of data sources to each log data set the total number of log data sets is also unlimited 7 2 7 2 7 2 7 2 Analyze data Analyze data Analyze data Analyze data Logged data can be visually evaluated...

Page 10: ...elect the position to be displayed then release the button This function can be used to zoom in and out Use the mouse wheel or select the area to be displayed You can reset the zoom settings by dou bl...

Page 11: ...the time difference between sensor data continuously stored in memory and thereby the time period displayed in charts If necessary each temperature sensor can be calibrated by adding an offset of 15...

Page 12: ...ion Display configuration Select Display from the device list below the VISION RGBpx entry In the upper area the ten configurable display screens are displayed In the lower area the selected screen ca...

Page 13: ...ault as well Confirm you se lection by clicking the check symbol in the lower right corner The configuration of the newly added LED controller can be modified in the lower area of the window Most effe...

Page 14: ...will notify you if audio analysis has been disabled in the aquasuite In this case please enable the feature in the general aquasuite configuration The general aquasuite configuration can also be used...

Page 15: ...nagement can be used to to save four configurations as profiles and activate them manually or automatically Profile manage ment is a software feature of the aquasuite and requires a USB connection to...

Page 16: ...USB port is explicitly specified for a current of at least 1 Amp by the manufacturer If the maximum per specified for a current of at least 1 Amp by the manufacturer If the maximum per specified for...

Page 17: ...block with the Out element The resulting virtual sensor can be used within the aquasuite software for example for overview pages additionally it may be transmitted via USB connection to con nected de...

Page 18: ...se with the aquasuite without warranty for error free operation or perma nent availability Aqua Computer reserves the right to limit or cancel this service at any time 15 1 15 1 15 1 15 1 Data export...

Page 19: ...ta sets each containing up to 30 values can be configured In order to verify that data is being imported use the Data quick view feature in the aquasuite Navigate to Data from Aqua Computer service th...

Page 20: ...s configured for variable refresh rate or a modified refresh rate video analysis may fail please deactivate this func tion in the graphics settings of the operating system if necessary 16 7 16 7 16 7...

Page 21: ...and software activation device serial numbers and a calculated computer ID are transmitted to and stored on the update server No further personal information such as IP addresses are stored 17 17 17 1...

Page 22: ...a computer de You might also want to visit our forums and discuss our products with experienced moderators and thousands of members available 24 7 To get in direct contact with our customer support te...

Reviews: