background image

VISION

9.2.

9.2.

9.2.

9.2. Display screens

Display screens

Display screens

Display screens

For display mode, ten configurable screens are available. For each screen, one of
the versatile templates can  be selected and configured. Depending on the tem-
plate, data sources, texts and images can be configured. 
For the audio display pages, audio analysis must be activated and configured in
the aquasuite, see chapter 16.6.

10.

10.

10.

10. RGBpx configuration

RGBpx configuration

RGBpx configuration

RGBpx configuration

Select “RGBpx” from the device list below the “VISION RGBpx” entry. 

Please note that the number of integrated LEDs depends on the product. Irrespec-
tive of the product,  30 LEDs can  be configured in the VISION  RGBpx module,
even if a lower number of LEDs is in fact integrated in the product.

10.1.

10.1.

10.1.

10.1. Create and configure additional LED controllers

Create and configure additional LED controllers

Create and configure additional LED controllers

Create and configure additional LED controllers

New LED controllers can be added by clicking the plus symbol. Alterna-
tively,   use   the   right   mouse   button   and   select   “New”   from   the   context
menu. Select the desired effect from the superimposed list of available ef-

fects. The controller name can be altered from its default as well. Confirm you se-
lection by clicking the check symbol in the lower right corner. 
The configuration of the newly added LED controller can be modified in the lower
area of the window. Most effects offer extensive customization options such as col-
or selection or speed adjustment. Additionally, many effects can be configured to
modify effect parameters depending on current sensor data.
In total, up to four LED controllers can be configured.

10.2.

10.2.

10.2.

10.2. Modify existing LED controllers

Modify existing LED controllers

Modify existing LED controllers

Modify existing LED controllers

Existing LED controllers can be selected by clicking the corresponding col-
or bars, the configuration of the selected controller can then be modified
in the lower area of the window.

By clicking the gear symbol, the effect to be displayed can be changed and the
controller name can be altered. Confirm you selection by clicking the check sym-
bol in the lower right corner. 

10.3.

10.3.

10.3.

10.3. Modify LED assignments

Modify LED assignments

Modify LED assignments

Modify LED assignments

Existing LED controllers can be moved by using “drag&drop”on the corre-
sponding color bars. The horizontal position of the color bar defines the
position of the effect on the connected LEDs. The vertical position deter-

mines the priority of the LED controllers, if multiple controllers are assigned to a

© 2020

Aqua Computer GmbH & Co. KG

- 13 -

Gelliehäuser Str. 1, 37130 Gleichen

computer

aqua

Summary of Contents for VISION RGBpx

Page 1: ...and installation manual VISION RGBpx aquasuite version X 24 Current as of July 2020 All information contained in this manual is subject to change without prior notice All rights reserved 2020 Aqua Com...

Page 2: ...chart 7 6 8 User defined Images text drawing elements 8 6 9 Export and import of overview pages 8 7 Data quick view and data log aquasuite 9 7 1 Log settings 9 7 2 Analyze data 9 7 3 Manual data expor...

Page 3: ...eorder menu items 19 16 3 Units 20 16 4 Application start up 20 16 5 Service administration 20 16 6 Audio and video 20 16 7 Updates and update service 20 17 Technical details and care instructions 21...

Page 4: ...RGBpx 21822 cuplex kryos sTRX4 with VISION RGBpx 21822 cuplex kryos sTRX4 with VISION RGBpx 21822 The cuplex kryos NEXT ships with a separate installation manual Install the water block according to t...

Page 5: ...llation For installation and update service vali dation an internet connection is required The latest aquasuite version may also be installed if no suitable update service pe riod has been found in a...

Page 6: ...desktop mode for an overview page by clicking the monitor symbol in the list of overview pages Desktop mode can only be enabled for one overview page at a time With desktop mode enabled elements of t...

Page 7: ...unit can be con figured for individual values 6 6 6 6 6 6 6 6 Detailed data elements Detailed data elements Detailed data elements Detailed data elements If the currently selected overview page is un...

Page 8: ...will require some programming experience for configuration 6 9 6 9 6 9 6 9 Export and import of overview pages Export and import of overview pages Export and import of overview pages Export and import...

Page 9: ...umber of data sources to each log data set the total number of log data sets is also unlimited 7 2 7 2 7 2 7 2 Analyze data Analyze data Analyze data Analyze data Logged data can be visually evaluated...

Page 10: ...elect the position to be displayed then release the button This function can be used to zoom in and out Use the mouse wheel or select the area to be displayed You can reset the zoom settings by dou bl...

Page 11: ...the time difference between sensor data continuously stored in memory and thereby the time period displayed in charts If necessary each temperature sensor can be calibrated by adding an offset of 15...

Page 12: ...ion Display configuration Select Display from the device list below the VISION RGBpx entry In the upper area the ten configurable display screens are displayed In the lower area the selected screen ca...

Page 13: ...ault as well Confirm you se lection by clicking the check symbol in the lower right corner The configuration of the newly added LED controller can be modified in the lower area of the window Most effe...

Page 14: ...will notify you if audio analysis has been disabled in the aquasuite In this case please enable the feature in the general aquasuite configuration The general aquasuite configuration can also be used...

Page 15: ...nagement can be used to to save four configurations as profiles and activate them manually or automatically Profile manage ment is a software feature of the aquasuite and requires a USB connection to...

Page 16: ...USB port is explicitly specified for a current of at least 1 Amp by the manufacturer If the maximum per specified for a current of at least 1 Amp by the manufacturer If the maximum per specified for...

Page 17: ...block with the Out element The resulting virtual sensor can be used within the aquasuite software for example for overview pages additionally it may be transmitted via USB connection to con nected de...

Page 18: ...se with the aquasuite without warranty for error free operation or perma nent availability Aqua Computer reserves the right to limit or cancel this service at any time 15 1 15 1 15 1 15 1 Data export...

Page 19: ...ta sets each containing up to 30 values can be configured In order to verify that data is being imported use the Data quick view feature in the aquasuite Navigate to Data from Aqua Computer service th...

Page 20: ...s configured for variable refresh rate or a modified refresh rate video analysis may fail please deactivate this func tion in the graphics settings of the operating system if necessary 16 7 16 7 16 7...

Page 21: ...and software activation device serial numbers and a calculated computer ID are transmitted to and stored on the update server No further personal information such as IP addresses are stored 17 17 17 1...

Page 22: ...a computer de You might also want to visit our forums and discuss our products with experienced moderators and thousands of members available 24 7 To get in direct contact with our customer support te...

Reviews: