AQUADUCT
The special tubes of the aquaducts must get separated before the use. It
can be helpful to separate the first millimeters with a knife. This area
must then be divided off.
6.6. Proper connection of the cuplex PRO and XT
Unlike channel coolers, the nozzle-
and
microstructure coolers cuplex XT and cu-
plex PRO have a predefined flow direc-
tion. For the cuplex PRO the water must
be conducted over the connection
placed centrically directly onto the mi-
crostructure, in the case of cuplex XT the
water is supplied over the connection
connected to the nozzle structure. The
nozzles accelerate the pouring water and provide a better heat transfer.
At both cooler variants the water is then led away by the lateral connec-
tion. The cooler reaches its full cooling performance only when connect-
ed in this way while in reversed operation the cooling performance is
sinificantly reduced.