REGEN TYPE:
TIME CLK DELAYED
Options:
Time Clock Delayed (System 4 Only)
(Default)
Meter Immediate (All System Types)
Meter Delayed Fixed Reserve (Systems 4 & 6 Only)
Example:
Time Clock Delayed
(Default)
VALVE TYPE:
STAGER-NOTCH CAM
Options:
2750
2850
2900
3150
3900
Stager - Notch Cam
(Default)
Example:
Stager - Notch Cam
(Default)
REMOTE SIGNAL
START:OFF
Options:
00:06:00 (Hours:Munutes:Seconds)
Range:
1 second to 99 minutes (1 hour, 39 minutes)
Example:
Off
(Default)
DISPLAY FORMAT:
US-GALLONS
Options:
U.S. - Gallons
(Default)
EU-Metric - Liters (Metric)
Example:
U.S. Gallons
(Default)
UNIT CAPACITY:
0300000 GRAINS
Options:
Grains (in U.S. Format)
(Default)
Grams (in Metric Format)
Example:
0300000 Grains
(Default)
CAPACITY SAFETY
FACTOR:
00%
Range:
0 to 50%
Example:
00%
(Default)
FEED WATER
HARDNESS: 15 GPG
Range:
1 to 199 Grains/Gallon (U.S. Format)
2 to 199 miligrams CaCO
s
/L (Metric Format)
Example:
15 GPG (U.S. Format)
(Default)
TRIP POINT 1:
000 gpm
Range:
2 to 4 Valves in the System
NOTE: This screen will not display for System Type 4.
NOTE: In European Units - Liters (Metric) mode, the display will be in
24-hour time.
NOTE: In U.S. - Gallons mode, the display will be in 12-hour time.
NOTE: Use the Shift button to move to the left.
Range:
1 to 9,900,000 Grain Capacity in U.S. Format
1.0 to 190,000 grams CaCO
3
Capacity in Metric Format
NOTE: Use the Shift button to move to the left.
NOTE: Use the Shift button to move to the left.
NOTE: This screen will only display on the lead unit for System Types 6 & 7.
For all other System Types, it will display for all units.
NOTE: Display will only appear on the master timer and it must be
programmed as valve position #1. Use the Shift button to change each
decimal position.
NOTE: This screen will only display for System 14.
TRIP POINT 2:
gpm
NOTE: This display will not be viewed in System 14.
NOTE: Display will only appear on the master timer and it must be
programmed as valve position #1. Use the Shift button to move one space
to the left.
TRIP DELAY 1:
30 SECONDS
NOTE: This screen will only display for System 14.
1 to 997 gpm
1 to 3997 Lpm
2 to 998 gpm
VALVE ADDRESS:
#2
Options:
Valve Address #1 (First Control Valve)
Valve Address #2 (Second Control Valve)
(Default)
Valve Address #3 (Third Control Valve)
Valve Address #4 (Fourth Control Valve)
SYSTEM TYPE:
4
SINGLE UNIT
Options:
System 4 (single unit)
System 5 (2-4 units) - Parallel Interlock
System 6 (2-4 units) - Parallel Series Regeneration
System 7 (2 units) - Alternating
System 9 (2-4 units) - Alternating
System 14 (2-4 units) - Demand Recall
Example:
System Type 4, Single Unit
Example:
Valve Address #2 (Second Control Valve)
(Default)
SYSTEM SIZE:
2 VALVES
Options:
2 Valves in the System
(Default)
3 Valves in the System
4 Valves in the System
Example:
2 Valves in the System
(Default)
REGEN TYPE:
TIME CLK DELAYED
Example:
Time Clock Delayed
(Default)
SELECT LANGUAGE:
ENGLISH
Options:
English
Espanol
Portugues
Deutsch
Francais
Example:
English
Range:
2 to 4 Valves in the System
NOTE: This screen will not display for System Type 4.
NOTE: This screen will not display for System Type 4.
MASTER PROGRAMMING MODE FLOW
CHART
CAUTION
Before entering Master Programming, please
contact your local professional water dealer.
When the Master Programming Mode is entered, parameters
can be set to make the timer(s) function as needed.
NOTE: Depending on current option settings, some
displays cannot be viewed or set.
Entering Master Programming Mode
1. Press and hold the Shift and Up buttons for 5 seconds.
OR
2. Set the time of day display to 12:01 PM or 12:01HR. Press
and hold Up or Down buttons to set the time. Then press
the Up and Down buttons at the same time for 5 seconds.
Exiting Master Programming Mode
1. Press the Extra Cycle button once per display until all
are viewed. Master Programming Mode is exited and the
normal display screen appears.
2. To exit the Master Programming Mode without saving
changes, press the Diagnostic button.
NOTE: If no keypad activity is made for 5 minutes while
in the Master Programming Mode, or if there is a
power failure, no changes will be saved, and the
unit will go back to the main display screen.
Resets
Soft Reset:
Press and hold the Up and Down buttons for 25
seconds until 12:00PM (or 12:00HR) appears. This resets all
parameters except for the
meter totalizer volume.
Master Reset:
Hold the Extra Cycle button while powering up
the unit. This resets all of the parameters in the unit. Check
and verify the choices selected in Master Programming Mode.
NXT Stager Controller