TROUBLESHOOTING

Detected Errors

If a communication error is detected, an Error Screen will alternate with the main (time of day) screen every few seconds. 

All units In Service remain in the In Service position.

All units in Standby go to In Service.

Any unit in Regeneration when the error occurs completes Regeneration and goes to In Service.

No units are allowed to start a Regeneration Cycle while the error condition exists, unless they are manually forced

into Regeneration.

When an error is corrected and the error no longer displays (it may take several seconds for all of the units in a

system to stop displaying the error message), the system returns to normal operation.

NOTE: During the error condition the control continues to monitor the flow meter and update the volume 

remaining. Once the error condition is corrected all units return to the operating status they were in prior to 

the error. Regeneration queue is rebuilt according to the normal system operation. Or, if more than one unit 

has been queued for regeneration, then the queue is rebuilt according to which one communicates first.

Message Displayed

Cause For Error

Correction

Flashing time

Power outage.

Program time by holding UP on Unit #1.

Detected Error = Matching Address Two or more units programmed with the same valve 

address number.

Program each unit with unique valve 

address number in Master Programming.

Detected Error = Program Mismatch Master program parameters do not match between two or 

more controls.

Confirm Master Programming for each unit.

Detected Error = No Message #1

No power to Control #1.

Power Control #1.

Communication Cable to Valve Address #1 bad or missing.

Connect or replace Communication Cable.

Detected Error = No Message #2

No power to Control #2.

Power Control #2.

Communication Cable to Valve Address #2 bad or missing.

Connect or replace Communication Cable.

Detected Error = No Message #3

No power to Control #3.

Power Control #3.

Communication Cable to Valve Address #3 bad or missing.

Connect or replace Communication Cable.

Detected Error = No Message #4

No power to Control #4.

Power Control #4.

Communication Cable to Valve Address #4 bad or missing.

Connect or replace Communication Cable.

Detected Error = E2 Reset Unit

This message appears after a software reset.

Reprogram control using Master 

Programming section.

Test Mode

Circuit Board was not programmed at factory.

Replace Circuit Board.

Black Squares on screen

Bad Circuit Board.

Replace Circuit Board.

INI on screen for more than 2 

minutes

Circuit board not getting feedback from cycle switch.

Inspect Motor - should be rotating.
Connect wire harness to cycle switch.
Check Cycle Micro Switch.

CHG on screen for more than 2 

minutes

Control programmed incorrectly as 2900 or 3900 valve type. Reprogram unit as Stager Valve type.

SERVICE ASSEMBLIES

48-00 ES Stager Assembly

61808-01 ....................Stager Assy, 48-00, NXT 24VAC, HMG No 2nd Aux Switch

61808-02 ....................Stager Assy, 48-00, NXT 24VAC, SA, 2nd Aux Notched in Service

61808-03 ....................Stager Assy, 48-00, NXT 24VAC, SC, 2nd Aux Notched In Backwash

61808-10 ....................Stager Assy, 48-00, Inverted, NXT 24VAC, HMG No 2nd Aux Switch

61808-20 ....................Stager Assy, 48-00, Inverted, NXT 24VAC, SA, 2nd Aux Notched in Service

61808-30 ....................Stager Assy, 48-00, Inverted, NXT 24VAC, SC, 2nd Aux Notched In Backwash

1074817......................Kit, Internal Parts, 48-00 Stager

61817-01 ....................Cam Assy, 48-00 NXT, HMG, no 2nd Aux Cam

61817-02 ....................Cam Assy, 48-00 NXT, SA, 2nd Aux Notched in Service

61817-03 ....................Cam Assy, 48-00 NXT, SC, 2nd Aux Notched in Backwash

51-06 ES Stager Assembly

61967-01 ....................Stager Assy, 51-06, NXT 24VAC, HMG, No 2nd Aux Switch

61967-02 ....................Stager Assy, 51-06, NXT 24VAC, SA, 2nd Aux Notched in Service

61967-03 ....................Stager Assy, 51-06, NXT 24VAC, SC, 2nd Aux Notched in Backwash

61967-04 ....................

Stager Assy, 51-06, NXT 24VAC, SH, 2nd Aux Notched in Refill

1074888......................Kit, Internal Parts, 51-06 Stager

61968-01 ....................Cam Assy, 51-06 NXT, HMG, No 2nd Aux Switch

61968-02 ....................Cam Assy, 51-06 NXT, SA, 2nd Aux Notched in Service

61968-03 ....................Cam Assy, 51-06 NXT, SD, 2nd Aux Notched in Backwash

NXT Stager Controller     AU11

Summary of Contents for NX48

Page 1: ...guide for service of the controller only System installation requires information from a number of suppliers not known at the time of control manufacture This product should be installed by a plumbin...

Page 2: ...ure 140 F 60 C Operate where ambient temperatures are above 32 F and below 110 F Pressure Maximum control fluid pressure 125 psi 8 5 bar Control fluid can be either water or air and must be equal to o...

Page 3: ...s flow meter sensor input Regeneration of a unit will begin after the other control has left Standby and returned to Service When the Regeneration cycle is complete the regenerated unit will enter Sta...

Page 4: ...Three Meters 1 2 3 4 5 The third tank returns to Standby as demand decreases past the second trip point Standby Flow Split Between Two Meters 1 2 3 4 6 Tanks return to Standby due to decreased total...

Page 5: ...n Service LCK Lock Lock will be displayed when contact closure is applied across the interlock terminals on the circuit board See the Network Communication Cables Connections section of this manual LE...

Page 6: ...mer is fully inoperative and any calls for regeneration are delayed The timer upon power re application resumes normal operation from the point that it was interrupted NOTE A flashing Time of Day disp...

Page 7: ...ress 2 Second Control Valve Default Valve Address 3 Third Control Valve Valve Address 4 Fourth Control Valve SYSTEM TYPE 4 SINGLE UNIT Options System 4 single unit System 5 2 4 units Parallel Interloc...

Page 8: ...Hours Minutes Seconds CYCLE 4 OFF Example Off Default 48 00 Stager CYCLE 4 00 12 00 Example Refill 00 12 00 Default 51 09 Stager Hours Minutes Seconds CYCLE 5 OFF Example 2 to 998 gpm 1 to 3997 Lpm 3...

Page 9: ...s resumed 3 Push and release the D button at anytime during diagnostic mode and the timer will exit the mode 4 Depending on the current controller programming certain displays may not be able to be vi...

Page 10: ...Start c c c c c c c c c c c c c c c c c c c c c Aux Relay Output End c c c c c c c c c c c c c c c c c c c c c Chemical Pump x x x x x x u u x x x x x x x x CPO Aux Relay Volume c c c c c c c c c c c...

Page 11: ...ould be left open or discharged to unrestricted or open drain DO NOT plug or restrict drain port 3 Connect the 1 8 NPT control ports to appropriate valves Refer to tubing schematic provided in the Plu...

Page 12: ...Note C Program Cycle 2 time to 00 00 00 for filter operation 4 POSITION FILTER Drain Line Flow Control not shown Note B Inverted Stager types will have these ports pressurized Inverted Stager to be us...

Page 13: ...DRAIN 2B UNIT B 4B 6B 1B 3B RAW WATER To Additional Tanks As Required SERVICE NOTE All valves normally open pressure to close NOTE Valve 2 for each tank is controlled by solenoid for system 7 9 14 NOT...

Page 14: ...installed at the factory is a universal type It is plumbed in an energize to close configuration when service outlet valve is normally open When a tank enters Regeneration or Standby the solenoid is...

Page 15: ...1 ES NEMA4 Solenoid 61784 Kit 48 51 ES 3214 NXT CKT Board Keypad 61764 Cable Assy Communication CAT 5 5 Meters Long 1075499 Switch Micro 40941 Wire Harness Upper Drive 1075502 Wire Harness 2nd Aux Swi...

Page 16: ...WIRING DIAGRAM 48 51 NXT STAGER CONTROLLER NXT Stager Controller AU11...

Page 17: ...No power to Control 3 Power Control 3 Communication Cable to Valve Address 3 bad or missing Connect or replace Communication Cable Detected Error No Message 4 No power to Control 4 Power Control 4 Com...

Page 18: ...AQ Matic or its affiliates All other registered and unregistered trademarks and logos are the property of their respective owners Because we are continuously improving our products and services AQ Ma...

Reviews: