Compressed air connection
Warning!
Compressed air must be free of oil
and humidity. Contamination of
compressed air may result in a poor
cartridge filtration, decreased
cleaning and reduced life time.
Purge the compressed air line to
remove any debris prior to connecting
air line to the dust collector air tank.
Shut off the compressed air system and
purge all air lines prior to servicing or
maintaining the collector.
Locate the pneumatic air tank(s) behind the
Maxiflo-VC
dust collector
.
Connect air line to the tank(s) using pipe
seal. Check for possible leak(s).
Note :
The use of an air dryer is strongly
recommended to avoid any problem related
to humidity in the compressed air system.
Install a shut off valve, pressure regulator and
filter on the compressed air line. Those
components are not supplied by
A.Q.C.
unless
required by the customer.
All components must meet a maximum 90 psig
pressure.
NEVER ALLOW MORE THAN
100 PSIG
. Damages to components may occur.
Ventilation ducting
·
The dust collector should be installed as
close as possible to the source of dust in
order to minimize the length of ventilation
ducting.
·
Do not install short radius elbows.
·
Install taps with 30 degrees inlet or less.
·
Do not install straight T taps.
·
Join ducting using tapping screws and
caulking for a proper seal.