Portable filtration units
19
13.4.2 MAXICART
1 .
Push the two (2) dust drawer levers down.
2 .
Slide the dust drawer out of the unit (6). Lift cartridges off the drawer (7).
3 .
Dispose of cartridges in a safe manner and according to environmental regulations.
4 .
Install a new cartridges. Ensure new cartridges are "sitting" firmly on the drawer cartridges
holder.
5 .
Push the dust drawer back into the unit and push dust drawer levers up.
6.
Ensure cartridges gaskets are firmly set against the upper part of filter housing.
Note:
for better and safe performance, use same cartridge material and properties.
5
5
6 7
8
9
3
4
13.5 Replacement of charcoal filter/MAXIROLL
Follow these next steps to replace the charcoal filter.
1 .
Open cabinet access door.
2 .
Remove the charcoal filter (on left side of unit). Dispose of
filter following existing environmental rules and regulations.
3 .
Slide new charcoal filter on its tracks and close access door.
13.6 Replacement of charcoal filter/MAXICART
Follow these next steps to replace the charcoal filter.
It is not necessary to open the cabinet access door to replace the
charcoal filter. The filter is located behind the clean air outlet at
the rear of the unit.
1.
Remove the screws holding the air louver into place.
2 .
Slide used charcoal filter out of it’s track and dispose of
filter following existing environmental rules and regulations
3 .
Slide new charcoal filter on it’s tracks and screw louver back
into place.