7.2 Seeding shaft motor
In this menu, you can specify the type of motor that is installed in the spreader.
Perform the following actions to open the programming menu for the blower fan /
spreading plate:
Press and hold the on/off button
and briefly press the seeding shaft
button at the same time (see
Fig.: 7).
Repeatedly pressing the seeding
shaft button switches between
settings E01 (P8 gear motor) or
E02 (P17 gear motor).
E01:
P8 gear motor (standard setting)
for pneumatic seed drills PS 120-500
for multi-metering systems (MDG, MDP, MDS, MDC)
E02:
P17 gear motor:
for pneumatic seed drills PS800, PS1200 and PS1600
for universal metering unit series (UD)
The setting is saved using the on/off button or the blower fan button.