CHAPTER 4
OPERATING INSTRUCTIONS
Entire Contents Copyright
2006
by Adaptive Power Systems, Inc. (APSI) • All Rights Reserved • No reproduction without written authorization from APSI.
FC200 SERIES OPERATIONS MANUAL
4 - 18
FC200-000-02.2
Interpreting Error Messages
Frequency
Display
Output Current Exceeded 105%.
If the output current exceeds 105% of the rated
output, the FREQUENCY display will show OCP (Over Current Protect); an alarm will
sound; the OUTPUT/RESET LED will flash; and the VOLTAGE and CURRENT displays
will show the corresponding values at the time of overload.
Frequency
Display
Output Current Exceeded Hi-A Limit.
If the output current exceeds the set current high limit value,
the FREQUENCY display will show HI-A; an alarm will sound; the OUTPUT/RESET LED will flash;
and the VOLTAGE and CURRENT displays will show the corresponding values at the time of the over-
current.
Frequency
Display
System Critical Temperature Exceeded.
If any of the system’s critical temperatures
are exceeded, the FREQUENCY display will show OtP (Over temperature Protect). This
signifies overheating. An alarm will sound; the OUTPUT/RESET LED will flash; and the
VOLTAGE and CURRENT displays will show their corresponding values at the time of the
over-temperature.
Frequency
Display
Output Voltage Limit Exceeded.
If the output voltage exceeds the voltage setting by
more than 5V on the 0-150V range or 10V on the 0-300V range, the FREQUENCY display
will show OVP (Over Voltage Protect); an alarm will sound; the OUTPUT/RESET LED will
flash; and the VOLTAGE and CURRENT displays will show the corresponding values at the
time of over-voltage.