Error messages are displayed because of the following conditions:
Fail Under voltage occurred during startup
OCP Output current exceeded 110% of units maximum-rated value
Hi-A Output current exceeded the set current high limit value
LoDC Inverter power supply voltage less than 80% of internal bus voltage
HiDC Inverter power supply voltage greater than 120% of internal bus voltage
AcLP Input power was interrupted and then resumed
FUSE Fuse opened
Igbt Insulated Gate Bipolar Transistor (IGBT) overloaded
OtP System's critical temperature was exceeded
OVP Output voltage was high
LVP Output voltage was low
OPP Output power was high