Installation
4.3 ELECTRICAL CONNECTIONS
Attenzione
!
•
The operator shall always be protected upstream by a 6A automatic differential switch with 30 mA actuation point and
contact opening over 3 mm.
•
The electrical installation shall be in compliance with the regulations in force in the installation country.
•
Do not use intercom or phone cables.
4.3.1 Useful advice
1. For the connection to the power source, use a cable with a minimum cross-section of 2 x 1.5 mm
2
.
2. For the controls (
open - common - close
) and (centralised open - common - centralised close and safety contact),
use cables with a cross-section of 3 x 0.25 mm
2
for lengths less than 5 metres; or cables with a cross-section
of 3 x 0.5 mm
2
for lengths over 5 metres.
3. For extensions of the motor power cables, use cables with a minimum cross-section of 2 x 0.75 mm
2
for lengths less
than 5 metres; or cables with a minimum cross-section of 2 x 1.5 mm
2
for lengths over 5 metres.
4. For extensions of the electric stop cables, use cables with a minimum cross-section of 2 x 0. 5 mm
2
for lengths less
than 5 metres; or cables with a minimum cross-section of 2 x 1 mm
2
for lengths over 5 metres.
4.3.2 Connecting the motor cables
Double-wing
•
Loosen the four cross-slotted screws on the corners of the box containing the electronic card and open the cover
• Shut the two wings and check which of them rests on the other (i.e. check which one closes second), then take the
red-black wires of the corresponding geared motor (indicated as
Mot1
) and proceed as follows:
A)- Fit the wires of gear motor (
Mot1
) that will close last (wing above) into the cable bushing
B)- Disconnect the removable 8-pole terminal board (
M2
) positioned on the right in the lower part of the electronic
card and connect the
red
wire to terminal
6
and the
black
wire to terminal
7
.
C)- Take the red-black cable of gear motor (indicated as
Mot2
) and, after having inserted it into the cable bushing,
connect the
red
wire to terminal
9
and the
black
wire to terminal
8
of the removable terminal board (
M2
).
Single-wing
For the connections of the single-wing, use only the connection to gear motor (
Mot1
).
4.3.3 Connecting the control accessories
Local controls -
Insert the cable into the cable bushing, then connect the wires to terminal board (
C2
) as
shown in the fi gure.
1
= open
2
= close
3
= common
Centralised controls and safety contact -
Connect the wires on the terminal board (
J2
) as shown in the fi gure.
• centralised
opening
• centralised
closing
• safety
• common
4.3.4 Connection to the power network
Take the power cable (not standard supplied) and insert it into the bushing of the control unit box.
Remove terminal board
(M1)
and connect the cable wires as follows
Blue
=
N
/ neutral
Brown/Black/Grey
=
L
/ phase