background image

 

SC 230

 

 
 

LAYOUT Funciones SC230 y características técnicas 

 

TRIMMER 

DSW

DESCRIPCIÓN

 

OFF

 

ON

 

1 C

IERRE AUTOMÁTICO

 

I

NHABILITADO

(1) H

ABILITADO

(2) 

2 F

UNCIONAMIENTO 

S

EQ Y 

P

ED

 

I

NHABILITADA

 

H

ABILITADA

 

3 F

UNCIÓN DE CORTESÍA 

(3) 

I

NHABILITADA

 

H

ABILITADA

 

4 F

UNCIÓN PARA CONDOMINIO 

(4) 

I

NHABILITADA

 

H

ABILITADA

 

5 S

OFT 

S

TART

 

I

NHABILITADA

 

H

ABILITADA

 

6 I

NTERMITENCIA PREVIA

 

I

NHABILITADA

 

H

ABILITADA

 

7 D

IRECCIÓN DE APERTURA

 

I

ZQUIERDA

 

D

ERECHA

 

8 T

IPO DE ENTRADA 

S

AF

 

D

IGITAL

 

R

ESISTIVO

 

9 F

UNCIÓN SALIDA 

+TST 

P

ARPADEANTE

 

P

RUEBA DE 

SEGURIDAD

 

10 L

IBRE

 

 

 

 

TR1

D

ELAY

 

Regula el tiempo de 
parada de 1 a 120 
segundos. 

TR2

T

ORQ

 

Regula el par motor 

TR3

SL 

Regula la velocidad en 
fase de ralentización. 
(5) 

TR4

B

RK

 

Regula la acción del 
freno al final del 
movimiento 

TR5

S

ENSE

 

Regula la sensibilidad 
antiaplastamiento 

 

1)  Apertura – Stop – Cierre – Stop – Etcétera 
2)  Apertura – Cierre – Apertura – Etcétera 
3)  La Función de cortesía habilita el cierre 5 segundos después de que las fotocélulas hayan recibido un impulso, 

independientemente del tiempo de trabajo. 

4)  La función de condominio inhabilita los mandos SEQ y PED durante la apertura. 
5)  Regulando el trimmer al máximo (rotación completa hacia la derecha) se excluye la ralentización. 
6)  El término desocupar indica una breve inversión del movimiento de la cancela y el relativo STOP del movimiento. 

 

Tabla 1- Datos técnicos 

 

TENSIÓN DE ALIMENTACIÓN MONOFÁSICA 

230V AC +6% -10% 

FRECUENCIA 

50 Hz 

ALIMENTACIÓN MOTOR 

230V AC +6% -10% 

TENSIÓN PARA DISPOSITIVOS EXTERNOS  

24 V DC +15% -10% 

CORRIENTE MÁX. DISPOSITIVOS EXTERNOS 

350 mA 

CONSUMO EQUIPO

(con accesorios conectados 

y en funcionamiento,excluidos los motores)

 

12 W 

POTENCIA ABSORBIDA (con motor) 

650W 

PROTECCIÓN DISPOSITIVO Y ACCESORIOS 

Fusible retardado F630mA (F1) 

PROTECCIÓN MOTOR 

Fusible de F5A (F2) 

CAMPO DE TEMPERATURAS 

-20° 

 +70° C interno a la caja 

GRADO DE PROTECCIÓN 

Depende del contenedor 

DIMENSIONES (LxHxP) mm 

107 x 100 x 50 (medidas aproximadas) 

18 

Summary of Contents for 41626/001

Page 1: ...e de vie du produit Afi n d viter des op rations incorrectes et de ne pas risquer des accidents s rieux lire attentivement ce manuel et respecter scrupuleusement les informations fournies Les instruc...

Page 2: ...alide per la sicurezza nei cantieri Delimitare il cantiere per impedire il transito a persone non autorizzate e non lasciare incustodita la zona di lavoro Installazione collegamenti elettrici e regola...

Page 3: ...adeguate misure correttive e applicare le segnalazioni previste dalle norme vigenti per individuare le zone pericolose Ogni installazione deve riportare in modo visibile l indicazione dei dati identif...

Page 4: ...rtura Chiusura Apertura Eccetera 3 La Funzione cortesia abilita la chiusura dopo 5 secondi che le fotocellule hanno ricevuto un impulso indipendentemente dal tempo di lavoro 4 La funzione condominiale...

Page 5: ...si luce spenta battenti chiusi M1 8 TST Se dip 9 ON Out Test sicurezze Se dip 9 OFF Out Lampeggiante a LED 7 MCL Avvolgimento Chiusura Motore 6 MOP Avvolgimento Apertura Motore 5 MCOM Comune Motore 4...

Page 6: ...locca tempo pausa impostato e CHIUDE PASSO PASSO CON STOP Stesso comportamento della logica PASSO PASSO con la differenza che Nella fase di apertura dando un comando SEQ il cancella si blocca dando un...

Page 7: ...connessa la schedina MCH2 Tale scheda fornisce due contatti NC e NO che vengono attivati per 1 sec alla ricezione di un impulso da un pulsante di telecomando associato a MCH2 Se nessun telecomando st...

Page 8: ...olizione dello stesso Esse devono essere consegnate all utilizzatore e devono essere lette attentamente poich contengono importanti avvertimenti per l uso e la manutenzione Questa apparecchiatura deve...

Page 9: ...e the working area unattended Installation electrical connections and adjustments must be carried out in a professional manner in compliance with the good manufacturing and workmanship regulations in...

Page 10: ...ut a risk analysis and check that the system does not feature crushing or shearing points If necessary corrective measures must be implemented and signals required by current regulations must be appli...

Page 11: ...ing Closing Opening Etc 3 The Courtesy function enables the closing 5 seconds after the photocells have received a pulse regardless of the working time 4 The condominium function disables the SEQ and...

Page 12: ...ixed light swing gates NOT closed light off swing gates closed M1 8 TST If dip 9 ON Safety devices Test Out If dip 9 OFF LED flashing light Out 7 MCL Motor Closing Winding 6 MOP Motor Opening Winding...

Page 13: ...STEP WITH STOP It works with the same logic of the STEP STEP but with the following differences During opening if a SEQ pulse is sent the gate will stop a further pulse will make the gate close Durin...

Page 14: ...CH2 CN2 connector can be connected to the coupon MCH2 This board provides two NC and NO contacts that are activated for 1 sec at the reception of a pulse from a remote control button associated with M...

Page 15: ...roduct throughout its life cycle up until decommissioning It should be stored in a accessible place ready for immediate reference The instructions and warnings must be given to the user and then read...

Page 16: ...rigurosamente las normas nacionales de aplicaci n para la seguridad en las obras Delimitar la obra para impedir el tr nsito a personas no autorizadas y no dejar la zona de trabajo sin vigilancia La in...

Page 17: ...i es necesario debe implementar las medidas de correcci n adecuadas y aplicar las se alizaciones previstas por las normas vigentes para identificar las zonas peligrosas Toda instalaci n debe exhibir d...

Page 18: ...tc tera 3 La Funci n de cortes a habilita el cierre 5 segundos despu s de que las fotoc lulas hayan recibido un impulso independientemente del tiempo de trabajo 4 La funci n de condominio inhabilita l...

Page 19: ...luz fija las hojas batientes NO est n cerradas luz apagada las hojas batientes est n cerradas M1 8 TST Si dip 9 es igual a ON Out Test seguridades Si dip 9 es igual a OFF Out parpadeante en LED 7 MCL...

Page 20: ...TOP El mismo comportamiento de la l gica AUTOM TICA SUPER salvo que El mando SEQ en fase de cierre bloquea la cancela y un siguiente mando la ABRE El mando SEQ en fase de apertura bloquea la cancela d...

Page 21: ...il secondo comando dell MCH2 col Canale del radiocomando Premere fino il pulsante P2 un quando il llev PROG comincia un lampeggiare no rilasciare P2 correo attendere che il pi veloce lampeggio divent...

Page 22: ...a instalaci n el ctrica Se recuerda que las bater as no est n cubiertas por la garant a por ser consideradas material de consumo Se recomienda no desechar la bater a en el medio ambiente sino deposita...

Page 23: ...al ajeno Aprimatic s r l declara que el dispositivo SC230 cumplen con los requisitos esenciales y otras exigencias relevantes de la Directiva 1999 5 EC Aprimatic srl Via Emilia 147 40064 Ozzano Emilia...

Page 24: ...SC 230 Aprimatic srl Via Emilia 147 40064 Ozzano Emilia BO Italy Tel 39 051 6960711 Fax 39 051 6960722 info aprimatic it www aprimatic it 24...

Reviews: