SC 230
LAYOUT of SC230 functions and technical specifications
TRIMMER
DSW
1
DESCRIPTION
OFF
ON
1 A
UTOMATIC RECLOSING
D
ISABLED
(1) E
NABLED
(2)
2 S
EQ AND
P
ED OPERATION
D
ISABLED
E
NABLED
3 C
OURTESY FUNCTION
(3)
D
ISABLED
E
NABLED
4 C
ONDOMINIUM OPERATION
(4)
D
ISABLED
E
NABLED
5 S
OFT
S
TART
D
ISABLED
E
NABLED
6 P
RE
-
FLASHING
D
ISABLED
E
NABLED
7 O
PENING DIRECTION
L
EFT
R
IGHT
8 S
AF
I
NPUT TYPE
D
IGITAL
R
ESISTIVE
9 O
UTPUT FUNCTION
+ TST
F
LASHING LIGHT
S
AFETY DEVICE TEST
10 S
PARE
TR1 D
ELAY
It adjusts stop time from
1 to 120 seconds.
TR2 T
ORQ
It adjusts the torque of
the motor
TR3 SL
It adjusts the speed
during slowing down
phase. (5)
TR4 B
RK
It adjusts brake power at
the end of the movement
TR5 S
ENSE
It adjusts anti-crush
sensitivity
1)
Opening – Stop – Closing – Stop – Etc.
2)
Opening – Closing – Opening – Etc.
3)
The Courtesy function enables the closing 5 seconds after the photocells have received a pulse, regardless of the working time.
4)
The condominium function disables the SEQ and PED controls during opening.
5)
Slowing down is completely disabled if the trimmer is fully turned (full clockwise rotation).
6)
Disable means that it slightly reverses the drive and STOPS the movement.
Table 1- Technical data
SINGLE-PHASE POWER SUPPLY VOLTAGE
230V AC +6% -10%
FREQUENCY
50 Hz
MOTOR POWER SUPPLY
230V AC +6% -10%
EXTERNAL DEVICES VOLTAGE
24 V DC +15% -10%
EXTERNAL DEVICES MAXIMUM CURRENT
350 mA
MAXIMUM ABSORBED POWER (
with accessories connected and
functioning,excluding motors)
12 W
ABSORBED POWER (driving motors)
650W
ACCESSORIES AND EQUIPMENT PROTECTION
Delayed fuse F630mA (F1)
MOTOR PROTECTION
F5A (F2) fuse
TEMPERATURE RANGE
-20°
↔
+70° C inside container
PROTECTION CLASS
According to container
DIMENSIONS (LxHxD) mm
107 x 100 x 50 (indicative measures)
11