TABLE 2
– HUMIDIFIER SYSTEM SETTINGS
System setting
Description
Factory default setting (bold)
and setting range
Allowed
Humidifier
Operation
Selects when humidification is allowed
to occur relative to heating and fan
operation
NOTE: Without Fan
is only
available when Humidifier Installed
is set to
Yes/Standalone
It allows
humidification to occur without
activating an HVAC fan and should only
be used when the humidifier is mounted
independently of any HVAC system
Heat Only
Heat or Fan
Forces Fan
Without Fan
CAUTION
When
Humidifier Operation
is set to
Without Fan
the thermostat will turn on
humidification without energizing the HVAC fan. Do not select this option when the
humidifier is installed on the HVAC duct. Without airflow moisture can accumulate in the
duct resulting in significant damage.
TABLE 2
– HUMIDIFIER SYSTEM SETTINGS
System setting
Description
Factory default setting (bold)
and setting range
Humidifier
Reminder
Selects when the “Change Water Panel”
message is displayed
Off
150h Valve
300h Valve
600h Valve
1 per season
2 per season
Single or First
Reminder
Appears
Determines the month the first (or only)
“Change
Water Panel” message is displayed
October
November
December
January
February
March
April
May
June
July
August
September
Second
Reminder
Appears
Determines the month the second
“Change Water
Panel” message is displayed (Only
available when 2 reminders per season
is selected)
October
November
December
January
February
March
April
May
June
July
August
September