HVAC INSTALLER SYSTEM SETTINGS TABLE
The following table contains the system settings and their details Default settings are shown in
bold The availability of some settings is dependent upon the value of other settings
TABLE 1
– HVAC INSTALLER SYSTEM SETTINGS
System setting
Description
Factory default setting (bold)
and setting range
Equipment Type
NOTE:
Equipment Type related
settings will return to defaults if this is
changed
Heat/Cool
Heat Pump
O/B Energized For?
Selects O or B reversing valve
operation (Heat Pump mode only)
Cooling
Heating
Control Setup
Used to lockout heating or cooling
outputs (Heat/Cool mode only)
Heat & Cool
Heat Only
Cool Only
Heat Pump
Auxiliary Type
Selects auxiliary type (Heat Pump
mode only)
Gas/Oil Heat
Electric Heat
Fan Control in
Heating
Selects thermostat or equipment to
control the fan in heating (Heat/Cool
mode only)
Gas/Oil Heat
Electric Heat
SETUP AND TESTING
INSTALLER SETUP WIZARD AND
INSTALLER SETTING
The first time the thermostat is powered
up (or after a factory reset) it will enter the
Installer Setup Wizard
All Installer Settings
can be set through this process The
Installer Settings are also accessible in the
Installer Menu
HOW TO ENTER THE INSTALLER MENU:
1.
Press
Select
to enter the
Main Menu
2.
Use
or
to navigate to
Settings
,
press SELECT
3.
Press and hold
and
for 3 seconds
to unlock the
Installer
option
4.
Use
or
to navigate to
Installer
,
press SELECT Refer to the chart at right for
options
INSTALLER
MENU OPTIONS
DESCRIPTION
HVAC Settings
Essential HVAC
equipment (equipment
type, stages, etc)
HVAC Advanced
Advanced HVAC control
(effsets, deadbands,
staging, protection, etc)
IAQ Settings
Humidifier, Dehumidifier,
Air Cleaner, and
Ventilation configuration
Wireless Sensor
Connect/disconnect
wireless indoor and
outdoor sensors
Test
Installer test for
configured equipment
relay outputs
Reset
Reset all settings to
factory default
19