8
1.3.2 System 2
System with 2 tanks, 1 pump, 1 valve, 1 collector array and 3 sensors.
With this system you can add an extra function with 1 sensor (
Thermostat
, or
Cooling
function).
1.3.3 System 3
System with 2 tanks, 2 pumps, 1 collector array and 3 sensors.
With this system you can add an extra function with 1 sensor (
Thermostat
, or
Cooling
function).
1.3.4 System 4
System with 1 tank, 1 pump, 1 valve, 2 collector arrays with 2 different cardinal directions (East /
West) and 3 sensors. With this system you can add an extra function with 1 sensor (
Thermostat
,
or
Cooling
function).
1.3.5 System 5
System with 1 tank, 2 pumps, 2 collector arrays with 2 different cardinal directions (East / West)
and 3 sensors. With this system you can add an extra function with 1 sensor (
Thermostat
, or
Cooling
function).
System
3
T1
T1 _ _ _°F
T2 _ _ _°F
T4 _ _ _°F
P1 _ _ _ %
P2 _ _ _ %
T2
T4
System
4
T1
T4
T2
T1 _ _ _°F
T2 _ _ _°F
T4 _ _ _°F
P1 _ _ _ %
System
5
T1 T4
T2
T1 _ _ _°F
T2 _ _ _°F
T4 _ _ _°F
P1 _ _ _ %
P2 _ _ _ %
System
2
T1
T1 _ _ _°F
T2 _ _ _°F
T4 _ _ _°F
P1 _ _ _ %
T2
T4