The different command types and their corresponding parameters are as follows:
6.2.1 Keys and signals
PC Send: <0x41>, <0x01>, <0x20>, <0x01>, <Key Value>, <0x4f>
< The value of a specific front panel key >
KEY_PLAY
1
KEY_STOP
3
KEY_PAUSE
4
KEY_POWER
5
KEY_REC
6
KEY_SETUP
7
KEY_ENTER
8
KEY_SEARCH
10
KEY_DISPLAY
11
KEY_UP
13
KEY_DOWN
14
KEY_LEFT 15
KEY_RIGHT
16
KEY_MONITOR 36
JOG_L
128
JOG_R
129
KEY_SHUT_L8
130
KEY_SHUT_L7
131
KEY_SHUT_L6
132
KEY_SHUT_L5
133
KEY_SHUT_L4
134
KEY_SHUT_L3
135
KEY_SHUT_L2
136
KEY_SHUT_L1
137
KEY_SHUT_CT
138
KEY_SHUT_R1
139
KEY_SHUT_R2
140
KEY_SHUT_R3
141
KEY_SHUT_R4
142
KEY_SHUT_R5
143
KEY_SHUT_R6
144
KEY_SHUT_R7
145
SIGNAL_REC_IN
163
SIGNAL_ALARM_RESET 165
SIGNAL_REC_OUT 169
SIGNAL_ALARM_IN 189
SIGNAL_ALARM_OUT 209
6.2.2 COMMAND Types
6.2.2.0 Command (Main Category=0x02)
6.2.2.1 Handshake (Second Category=0x01)
PC Request: <0x41>, <0x01>, <0x20>, <0x02>, <0x01>, <0x00>, <0x4f>
DVR Response: <0x41>, <0x20>, <0x01>, <0x02>, <0x08>, <0x00>, <0x4f>
6.2.2.2 Request Time (Second Category=0x02)
PC Request: <0x41>, <0x01>, <0x20>, <0x02>, <0x02>, <0x00>, <0x4f>
DVR Response: <0x41>, <0x20>, <0x01>, <0x02>, <0x02>, <0x07>, <7 Time Value >, <0x4f>
The following case is an illustration of
< 7 Time Value>
2003/06/20 17:05:00 = <0xD3>, <0x07>, <0x06>, <0x14>, <0x11>, <0x05>, <0x00>
6.2.2.3 Set Time (Second Category=0x02)
PC Request: <0x41>, <0x01>, <0x20>, <0x02>, <0x02>, <0x07>, < 7 Time Value >, <0x4f>
The following case is an illustration of
< 7 Time Value>
2003/06/20 17:05:00 = <0xD3>, <0x07>, <0x06>, <0x14>, <0x11>, <0x05>, <0x00>
DVR Act: Changing the time and date.