LATCH GROUPING OPTIONS
NOTE: When a KTX24SSA-12 transmitter controls two RCR24SSA-6R
receivers, all relay response modes are available for all 12 channels.
However, Latched Groups are limited to two 6 channel groups as shown.
S3-1
S3-2
S3-3
S3-1
8
Master Reset Function
(optional)
In addition to the Latch Groups described above, the 6-channel receiver
provides an optional Master Reset function. If the Master Reset function
is enabled, pressing Button 6 on the transmitter will turn off any relay(s)
that is(are) energized (either latched or toggled) at that time. When the
Master Reset function is enabled, Relay 6 is nonfunctional (does not
respond to Button 6 on the transmitter), regardless of the Response
Mode to which it is configured (via DIP Switch S1-6). The Master Reset
function is enabled by setting DIP Switch S3-4 to its ON position.
Miscellaneous Considerations for Configuration
• When changing any DIP Switch settings, the receiver MUST be
disconnected from power.
Configuration changes do not take effect
until the receiver is powered up
(i.e. the DIP Switches are only
interrogated by the receiver’s microprocessor at power-up initialization).
• DIP Switch S1-7 and S1-8 are not used. They are reserved for future
product enhancements.
• For DIP Switches S3-1, S3-2, and S3-3 only the highest-numbered
switch is recognized if more than one is turned on. This does not apply to
S3-4 (Master Reset
).
LED Indicators (Receiver)
Power LED:
Indicates that voltage is applied to the receiver.
Relay LED’s (6):
They indicate for each relay whether the relay is
activated.
Learn LED:
Indicates when “Learn” mode is activated.
Controlling 120V Circuits and High Amperage Loads
The RCR receiver is not UL listed, and 110 or higher voltage circuits
should not be directly connected to the receiver relays. These circuits
can be controlled however by using a contactor with a 24-VAC coil (AW
PN 269006, 25A contactor).
For low voltage loads over 10 Amps, Applied Wireless offers internal 16A
relay option or high current relays (AWPN 269007, 30A 12VDC Relay)