9
RCR24SSA-6R Programming and Configuration
Frequency Setting (DIP Switch S2)
It is recommended that you do not change this setting unless needed.
In order for more than one system to operate in the same area, up to 16
different frequency settings are available. Remove the lid from the case
of the RCR24SS-6R receiver. S2 is a 4 position dip switch which is near
the edge of the board and can be set to up to 16 unique patterns that
correspond to 16 different frequency settings. The pattern set in the
receiver frequency switch has to match the pattern set in the transmitter
frequency switch, which is also a 4 position dip switch exposed when the
case is taken apart.
Bank Switch Setting
To allow 2ea RCR24SS-6R receivers to be used with 12 channel
transmitters an internal jumper setting is available. When the lid is
removed from the case of the RCR24SS-6R receiver, a jumper setting
near relay K5 in the 6 channel receiver is a 3 position header with a
jumper installed. If the jumper is installed between the center pin and the
pin marked “A” then the 6 relays will respond to Buttons 1 thru 6. If the
jumper is moved to between the center pin and the pin marked “B” then
the relays will respond to Buttons 7 thru 12.
10
Board Switch & Jumper Locations